Download Print this page

Baxi Bermuda PW5 Deluxe User Operating Instructions Manual page 5

Fireside gas central heating unit
Hide thumbs Also See for Bermuda PW5 Deluxe:

Advertisement

8
RESETTING THE BOILER:
(Electronic Controls Boiler)
(45/3E, 57/3E, 45/4E & 57/4E)
If the boiler lockout light is illuminated
it is necessary to reset the appliance.
To do this turn the boiler thermostat
control knob fully anti-clockwise to
the OFF position and wait 10
seconds. Turn the control knob to the
required setting. The boiler will
commence sparking providing the
water temperature is sufficiently cool.
(51/5)
If the indicator light is illuminated
red/or flashing red, it is necessary to
reset the appliance. To do this turn
the boiler thermostat control knob
fully anticlockwise to the OFF position
and wait until the light shows orange.
Turn the control knob clockwise to
the required setting. The boiler will
commence the ignition sequence.
9
TO LIGHT THE FIRE: Push in
and turn the fire control knob
slowly anti-clockwise to the positive
stop at position "
1". Just before
position "
1" is reached, a click will
be heard and the burner should light,
hold in the control knob for approx 15
seconds, release and turn to desired
position. If the burner fails to light,
turn the control knob to the OFF
position (
) and repeat until the
burner lights. Continue to hold in the
control knob for a further 15 seconds.
Release slowly and the burner should
stay alight.
CAUTION -
If the burner does not light
or stay alight, or if the flame goes out for
any reason, turn the control knob to the
OFF position (
) and wait for 3 minutes
before attempting to light the burner.
NOTE:
An electrical supply is not
needed to ignite the fire.
CONTROL KNOB POSITIONS: The
control knob has five positions giving
a choice of 4 settings, i.e.
Position
- OFF
Position
1 - IGNITION/PILOT
Position
1 - LOW
Position
2 - MED
Position
3 - MED/HIGH
Position
4 - HIGH
To adjust the fire to the required
setting, push in the control knob and
turn in the appropriate direction.
There is no 'Pilot Only' position-the
pilot and burner low rate light
simultaneously at position
When the control knob is turned from
1 to
the pilot is extinguished.
10
TO TURN THE FIRE OFF:
Push in the control knob and
turn clockwise to the OFF position( ).
Controls
Cover Panel
Position
Indicator
Button
Fire Control Knob
Controls
Cover Panel
Position
Indicator
Button
Fire Control Knob
1.
Controls
Cover Panel
PW5 Deluxe
Baxi Bermuda
PW5 Deluxe
C5W
(C5 shown)
C5
page 5
TO SHUT DOWN THE BOILER
Turn the fire control knob to the OFF
position ( ), and allow the fire to
cool.
Remove the controls cover panel at
the bottom of the fire by grasping it
firmly by its side edges and pulling
forwards.
To switch the boiler off for short
periods. (Manual Controls Boiler)
Turn the boiler thermostat knob to the
OFF position (
). The pilot will
remain alight.
To switch the boiler off for long
periods. (Manual Controls Boiler)
Turn the grey push button clockwise
and release. Turn the boiler
thermostat knob to the OFF position
(
).
To switch the boiler off. (Electronic
Controls Boiler) Turn the thermostat
knob to the OFF position (
If you are shutting down both the fire
and boiler, isolate the electrical
supply that serves the system
controls i.e. Timer/Programmer.
Replace the controls cover panel.
NOTE: If the boiler is left off for long
periods during cold weather, it is
recommended that the whole system is
drained to avoid frost damage. Advice on
draining the system can be obtained from
your Service Engineer.
).

Advertisement

loading

This manual is also suitable for:

Bermuda c5Bermuda c5w