EL296 Field Wiring Applications With Conventional Thermostat (Continued)
DIP Switch Settings and On-Board Links (See figure 60)
DIP Switch 1
Thermostat
Thermostat
Heating
Stages
2 Heat / 2 Cool
OFF
2 Heat / 2 Cool
OFF
with t'stat with
humidity control
2 Heat / 1 Cool
OFF
with t'stat with
humidity control
2 Heat / 1 Cool
OFF
TABLE 11
On Board Links Must Be Cut To Select
System Options
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W914
DEHUM
OR
HARMONY
CUT ON-BOARD LINK
W914
DEHUM
OR
HARMONY
DO NOT CUT ANY
ON-BOARD LINKS
Page 44
Wiring Connections
S1
FURNACE
T'STAT
TERM. STRIP
*
*Not required on all units
S1
FURNACE
T'STAT
TERM. STRIP
o
*Not required on all units
S1
FURNACE
T'STAT
TERM. STRIP
o
*Not required on all units
S1
FURNACE
T'STAT
TERM. STRIP
*
*Not required on all units
OUTDOOR
UNIT
OUTDOOR
UNIT
*
OUTDOOR
UNIT
*
OUTDOOR
UNIT