Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11: Sierra Products. Congratulations on purchasing your Kramer VS-88FO 8x8 3G HD-SDI Fiber Optic Matrix Switcher, which is ideal for the following typical applications: ...
Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer VS-88FO away from moisture, excessive sunlight and dust This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at http://www.kramerelectronics.com/support/recycling/.
Windows®-based software is included), RS-485, Ethernet and IR Laser Class I acc. 21 CFR 1040 and Class 1 per IEC 60825-1 compliance The VS-88FO is housed in a 19" 1U rack-mountable enclosure, and is fed from a 100-240V AC universal switching power supply. VS-88FO – Overview...
Remotely, by RS-232 or RS-485 serial commands transmitted by a PC, touch screen system, or other serial controller The Ethernet By default, the VS-88FO is controlled using the Kramer 3000 protocol (see Section 6.1.9 for details of how to switch to Protocol 2000 and...
Figure 1: VS-88FO 8x8 3G HD-SDI Fiber Optic Matrix Switcher Front Panel Feature Function IR Receiver The yellow LED illuminates when receiving signals from the infrared remote control transmitter POWER LED Illuminates when the unit is ON ALL Button Pressing ALL followed by an INPUT button, connects that input to all outputs OFF Button Pressing OFF+OUT disconnects that output from the inputs;...
Figure 2: VS-88FO 8x8 3G HD-SDI Fiber Optic Matrix Switcher Rear Panel Feature Function GENLOCK BNC Connector Connects to the genlock source Press to terminate the genlock source (75Ω) or release for looping TERM HI-Z/75Ω Pushbutton LOOP BNC Connector Connects to a display or the next chained Genlock connector Holds an SFP module in each OUT/IN receptacle (1 –...
Connecting the VS-88FO This section describes how to connect the VS-88FO. The VS-88FO can switch one of the eight fiber optic inputs to any or all of the eight fiber optic outputs, as the example in Figure 3 shows. Always switch off the power to each device before connecting it to your VS-88FO.
5. Connect the OUT connectors to up to eight fiber optic acceptors (for example, a Kramer 690R receiver connected to 3G HD-SDI displays). 6. Set the Machine # and termination DIP-switches (see Section 5.2.1). 7. Optionally, connect: A genlock source to the GENLOCK BNC connector ...
2. Pull the SFP module out by the bail (#4). 3. If needed, replace the protective cap over the fiber connectors. Note: When transporting or storing an unconnected device, replace the SFP caps to protect against dust. Figure 4: Installing the SFP Modules VS-88FO - Connecting the VS-88FO...
A master unit must be Machine #1. When connecting more than one VS-88FO, set a different Machine # for each unit. The units do not have to be numbered sequentially but each unit must have a unique machine number.
OFF. Connecting a PC or Controller to the RS-485 Port You can operate the VS-88FO over the RS-485 port from a distance of up to 1200 meters (3900ft) using any device equipped with an RS-485 port (for example, a PC).
For a master machine, assign MACH #1 with the address 0 (0000) or 1 (0001) set in the DIP-switches For the slave units, assign a unique MACH # from 2 to 15 for each VS-88FO slave. The units do not have to be sequentially numbered but they must have unique addresses 5.3.2...
5.5.1 Connecting the Ethernet Port Directly to a PC You can connect the Ethernet port of the VS-88FO directly to the Ethernet port on your PC using a crossover cable with RJ-45 connectors. This type of connection is recommended for identifying the VS-88FO with the factory configured default IP address.
4. Highlight either Internet Protocol Version 6 (TCP/IPv6) or Internet Protocol Version 4 (TCP/IPv4) depending on the requirements of your IT system. 5. Click Properties. The Internet Protocol Properties window relevant to your IT system appears as shown in Figure 7 Figure VS-88FO - Connecting the VS-88FO...
8. Click Close. 5.5.2 Connecting the Ethernet Port via a Network Hub or Switch You can connect the Ethernet port of the VS-88FO to the Ethernet port on a network hub or using a straight-through cable with RJ-45 connectors. 5.5.3...
Configuring the Ethernet Port Initially To initially configure the Ethernet port, download the K-UPLOAD Ethernet configuration software (from the Kramer Web site at http://www.kramerelectronics.com). Extract the file to a folder and create a shortcut on your desktop to the file.
Figure 11: Connect Screen 3. Connect a USB cable from a USB port on the PC to the USB port on the VS-88FO. (You can also connect to the PC using the Ethernet or a serial connector). 4. Check USB as the connection method and select the COM port from the USB drop down list.
Controlling Using the Ethernet Port You can control the VS-88FO over the RS-232/RS-485 port or the Ethernet using the Kramer K-Router application. If you are controlling a standalone unit using RS-232 or the Ethernet, configure the unit as master (MACH #1), see Section 5.2.1.
Use the front panel buttons to perform the following operations: 6.1.1 Power-On Display When the VS-88FO is powered on, the display briefly shows the 4-digit firmware version number and the genlock timing setting. Then the display changes to its normal operating display.
Page 26
2. Press the TAKE button to confirm the action. The 7-segment display stops flashing. The TAKE button stays lit. To confirm several actions (in CONFIRM mode), do the following: 1. Press each OUT-IN combination in sequence. The 7-segment display flashes. VS-88FO - Operating the VS-88FO...
Page 27
The LOCK key illuminates and the front panel keys are inactivated To unlock the front panel, press and hold the illuminated LOCK key until the light turns off. The front panel keys are activated VS-88FO - Operating the VS-88FO...
OUT 1 and OUT 2 at the same time. OUT 1 flashes briefly if the change was made correctly To revert to the Kramer 3000 protocol, press OUT 1 and OUT 3 at the same time. OUT 1 flashes briefly if the change was made correctly If an error is indicated, retry the previous action or choose a new action.
Kramer Web site at www.kramerelectronics.com updated in minutes using K-UPLOAD. The USB port is used for connecting the VS-88FO to a PC to transfer the data. Changing the Device Parameters To change the device parameters do the following: 1.
Press and hold Front Panel Press and hold Output 1 and Output Output 1 and Output 3 simultaneously 2 simultaneously Ethernet IP Address 192.168.1.39 TCP Port 5000 or 10001 or 50000 Subnet Mask 255.255.255.0 UDP Port 50000 VS-88FO - Default Communication Parameters...
® Note: If you are using Kramer’s Windows -based control software it operates only with Protocol 2000. If the VS-88FO is set to Protocol 3000, it automatically switches to Protocol 2000. Download the latest software from our Web site at http://www.kramerelectronics.com.
Page 34
CRLF – For machine messages; carriage return (ASCII 13) + line-feed (ASCII 10) Command chain separator character When a message string contains more then one command, a pipe ( '|' ) character separates each command. Spaces between parameters or command terms are ignored. VS-88FO - Kramer Protocol 3000...
Page 35
You can directly enter all commands using a terminal with ASCII communications software, such as HyperTerminal, Hercules, etc. Connect the terminal to the serial, Ethernet, or USB port on the Kramer device. To enter CR , press the Enter key. ( LF is also sent but is ignored by command parser).
3. Switch video input 3 to output 9 (non-existent). ~VID ERR003 CRLF 4. Get status of all video links. ~VID 2>1, 0>2, 1>3, 3>4 CRLF Command processing begins after entering CR . A response is sent for each command after processing. VS-88FO - Kramer Protocol 3000...
‘1’ or ‘on’ to lock front panel buttons Reset device RESET RESET OK Switch to protocol 2000* P2000 P2000 OK * Protocol 2000 has a command to switch back to ASCII protocol (like Protocol 3000) VS-88FO - Kramer Protocol 3000...
NET-MASK SUBNET_MASK Short form: NTMSK? Set gateway address NET-GATE GATEWAY_ADDRESS NET-GATE GATEWAY_ADDRESS RESULT Short form: NTGT Read subnet mask NET-GATE? NET-GATE GATEWAY_ADDRESS Short form: NTGT? Set DHCP mode NET-DHCP DHCP_MODE NET-DHCP DHCP_MODE RESULT Short form: NTDH VS-88FO - Kramer Protocol 3000...
Page 39
Short form: ETHP? PROTOCOL = TCP/UDP (transport layer protocol) PORT = Ethernet port that accepts Protocol 3000 commands 1-65535 = User defined port 0 - Reset port to factory default (50000 for UDP, 5000 for TCP) VS-88FO - Kramer Protocol 3000...
The following table lists the Hex values for a single machine (MACHINE # 1): OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 VS-88FO - Hex Table (Protocol 2000)
Kramer Protocol 2000 The VS-88FO is compatible with Kramer’s Protocol 2000, version 0.50. This RS-232/RS-485 communication protocol uses four bytes of information as defined below. The default data rate is 9600 baud, with no parity, 8 data bits, and 1 stop bit.
Page 42
NOTE 8 - The reply is as in TYPE 3 above, except that here the OUTPUT is assigned with the value 0 if the setup is not defined / no valid input is detected; or 1 if it is defined / valid input is detected. VS-88FO - Kramer Protocol 2000...
Page 43
(in real-time). For example, if input 3 is detected as invalid, the unit will send the HEX codes If input 7 is detected as valid, then the unit will send HEX codes VS-88FO - Kramer Protocol 2000...
Page 45
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found. We welcome your questions, comments, and feedback. Web site: www.kramerelectronics.com E-mail: info@kramerel.com SAFETY WARNING...