I40" Code Family: Analogue Pressure Switch; I50" Code Family: Washing Motor Problems - Electrolux ProClean RealLife EDW5xx Series Service Manual

Proclean reallife
Table of Contents

Advertisement

9.2.5

"i40" code family: analogue pressure switch

9.2.5.1
"i41" code
-
The alarm is defined if no signal is detected from the analogue pressure switch for more than 1 sec
or if the signal is out of range.
-
The programme stops and the error is displayed.
9.2.5.2
"i42" code
-
The alarm is defined if the signal originating from the sensor is not stable enough or is out of range
for an empty appliance.
-
The calibration is performed during the activation of the drain pump and immediately after to
guarantee that if the non-return valve is not sealed, the backflow of water does not corrupt the actual
calibration.
9.2.6

"i50" code family: Washing motor problems

9.2.6.1
"i51" code – asynchronous motor
-
Acoustic signal and visual alarm, depending on the appliance customisation; the programme is
suspended.
-
The washing pump runs without being activated by the software, the cause is a short-circuit.
-
The heating element is not activated.
-
If the alarm occurs, the fill solenoid valve is activated up to the level pressure switch tripping point,
then the cycle is suspended.
-
Time limit set: 8 sec.
9.2.6.2
"i52" code – synchronous motor
-
The alarm is signalled when an abnormal extra current of 1.3 Amps is detected.
9.2.6.3
"i53" code – asynchronous motor
-
The alarm is signalled when a current above the maximum limit allowed of 1.3 Amps is detected.
9.2.6.4
"i54" code – inverter motor with rotor locked
-
The alarm is signalled when the motor is locked at the start or during its actual activation.
-
Possible causes may be the presence of dirt, too large a load, mechanical problems on impeller.
9.2.6.5
"i55" code – motor control board over voltage
-
The alarm is signalled when the voltage detected on the motor control board is more than 400 V.
9.2.6.6
"i56" code – motor control board under voltage
-
The alarm is signalled when the voltage detected on the motor control board is less than 255 V.
9.2.6.7
"i57" code
-
The alarm is signalled if a voltage of more than 440 V or less than 215 V is detected.
9.2.6.8
"i58" code – washing pump connection
-
The alarm is signalled if an incorrect connection of the pump is detected, based on the current
measurements check.
-
Time limit set: 2 sec.
9.2.6.9
"i59" code – current measurement error on motor control board
-
The alarm is signalled if there is an error in reading the current on the motor control board
-
The condition is verified by the sum of currents of each of the phases, which should be nearly zero:
if this sum is more than 40mA for longer than 300 msec then an error condition occurs.