9 Alarm codes

9.1

Alarm Management

In "ProClean/RealLife" appliances, the alarm codes are defined in families of alarms and current alarms,
displayed as:
iXY
i = alarm indication
X = family of the alarm
Y = Current alarm
Caution:
Only the alarm family codes are displayed to the user.
The complete alarm code will be stored among the three alarms that can be stored by the appliance.
A new alarm code is only stored if it differs from the last one stored.
The three most recent alarm codes can be displayed only in Service Mode or using the Sidekick tool.
Appliances with a display will show the alarms by a number of flashes of the cycle end LD, such as in
"DIVA": i10=1 flash, i50=5 flashes, iB0=11 flashes