This manual contains important instructions for models SBP0400TBF-6U, SBP0600TBF-6U, SBP0800TBF-6U, SBP0400TBF-6U-LCD, SBP0600TBF-6U-LCD, SBP0800TBF-6U-LCD that should be followed during installation and maintenance of the UPS and batteries. Safety Caution! Maximum output power during reserve mode shall not exceed 240W for model...
Page 3
CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS Ce manuel contient des instructions importantes pour les modèles SBP0400TBF-6U, SBP0600TBF-6U, SBP0800TBF-6U, SBP0400TBF-6U-LCD, SBP0600TBF-6U-LCD, SBP0800TBF-6U-LCD qui doivent être suivies lors de l'installation et de la maintenance de l'onduleur et des batteries. Sécurité Attention! Puissance de sortie maximale en mode de réserve ne doit pas dépasser 240W pour le modèle...
System Description FRONT PANEL Power Switch LED Indicators AC Mode: Green lighting Battery Mode: Green flashing LCD back-light Power Switch BACK PANEL FOR LED & LCD USB Port AC Input 2 TBF™ power Circuit Breaker conditioned outlets 4 battery + TBF™...
Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware the Power Switch must be kept in the “ON” position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1.
Page 6
Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). Uninterruptible Power Supply COMPUTER Modem/Phone line Connection Plug incoming internet line into the “In” socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the “Out”...
Page 7
Tun On/Off The UPS will be turned on automatically at first plug-in. At this moment, press the power switch lightly to turn off the UPS. T o turn on the UPS again, just simply press power switch again. Please DO NOT punch it to extend the life of the power switch.
Page 8
Battery Removal (SBP400-800) Before replacing the battery, turn off the UPS and unplug the UPS cord from the wall outlet. Follow Chart 1 to remove the screw located on the bottom of the front panel and then open Chart 1 the front cover.
Page 9
Free Software Download SmartPower Systems provides a complete line of software solutions for standalone and networked computers, including SNMP POWER MANAGEMENT SOFTWARE support. FEATURES • Automatic Save and Shutdown for unattended PCs • Reboot/Shutdown scheduling • Self test scheduling • Power condition analysis •...
Troubleshooting Symptom Possible Cause Solution 1. Missing battery 1. Charge battery up to 8 hours No LED or no LCD display on the front panel 2. Replace with the same 2. Battery defect type of battery 3. Power switch is not 3.
Page 11
Specifications - 400VA - 800VA SBP0400TBF-6U SBP0600TBF-6U SBP0800TBF-6U MODEL SBP0400TBF-6U-LCD SBP0600TBF-6U-LCD SBP0800TBF-6U-LCD CAPACITY VA/W 400VA/240W 600VA/360W 800VA/480W Voltage 120VAC INPUT Voltage Range 89-145VAC Voltage 120VAC Voltage Regulation +/- 10% (Battery Mode) Frequency 50Hz/60Hz OUTPUT Frequency +/-1 Hz (Battery Mode) Regulation...
LIMITED PRODUCT WARRANTY We warrant this product to be free from defects in material and workman- ship for 2 years. The battery has a 4 year pro-rated warranty. If a product proves to be defective in material or workmanship during the warranty period, we will at our sole option repair or replace the product with a like product.