INDEX 1. PRODUCT INTRODUCTION ....................3 1-1 A ........................3 PPLICATIONS 1-2 P ..............4 OWER CONTROL AND MONITORING DIAGRAM 1-3 P ......................5 RODUCT EATURES 1-4 C ....................6 ONTROL AND INDICATORS 1-5 S ........................ 7 PECIFICATIONS 1-6 P ......................
Page 3
3-6 F ....................... 29 IRMWARE PGRADE 3-6-1 Firmware Upgrade ....................29 3-6-2 Download / Reset Configuration ................30 ATTACHMENT (A): HOW TO RETURN SMARTPOWER SETUP TO INITIAL VALUE..32 - 2 -...
1. Product Introduction The SMARTPOWER 2L is an Internet ready SNMP device designed with integrated versatile functions including power control, remote web administration, event alerts into one single unit, which helps system administrators or IT personnel to monitor and control their connected equipment and take preventive measures when needed.
LEDs for power status and control mode indication. Supports Power Start sequencing to prevent all of the connected devices from starting simultaneously to limit the in-rush current to SMARTPOWER 2L. Easy web setup for scheduling daily, weekly, monthly and yearly power operations on a specific outlet.
1-4 Control and Indicators Main Power Switch & Breaker Power Switch Indicating Light Protector Reset Indicating Light Power Input Power Indicating Light Power Switch Socket RJ45 Network Connect Port - 6 -...
1-5 Specifications Power Socket NEMA-15R Max. Main Output Current 12 Amp Power Input 85~264VAC 47~63Hz Power Frequency 50 - 60 HZ 0 – 60 ℃ Operating Temp. Shape Size 153 x 123 x 44 mm (W x D x H) Machine Net Weight 0.75 KG Consumption Efficiency...
1-7 Installation and Setup 1-7-1 Hardware Installation 1. Connect the power cord to the power inlet on SMARTPOWER 2L and to the utility service. 2. Plug the equipment into the output receptacles. 3. Connect the Ethernet cable to the Ethernet port.
6. Put SMARTPOWER 2L’s CD (provided) in the CD-ROM drive. 7. Launch the IP Search Utility program. 8. Click on the Refresh button to search for all of SMARTPOWER 2L’s in the LAN. A list of SMARTPOWER 2L will be displayed.
Page 11
Gateway and the Net Mask (Subnet) for the selected SMARTPOWER 2L in the list change. 10. Repeat Step number 8 and 9 for all of SAMRTPOWER 2L in the list. 11. Once all of SMARTPOWER 2Ls are setup, close the IP Search Utility program and turn the Windows Firewall back on.
2. Internet Web Operation In this Chapter, you can learn how to set up this intelligent power controller and configure the network setup, system time, power basic data, and how to operate power switch via network quickly. 2-1 Online Setup ①...
Page 13
2-2 Network Click on【System】tab from the menu bar of the web screen and then click on 【Network】next for configuring the IP address and network info of this device. - 12 -...
2-3 Time Synchronization The time zone that our SMARTPOWER 2L model adopts is 24-hour basis so you must set up the timer schedule on this basis to the switch can perform accordingly. When accessing this unit for the first time, you can have three time sync options to choose from.
Page 15
There are total of three system time synchronizers from the selection list: Sync with A Local PC Clock: Select this method if you want to set up the equipment system time to be the same as your PC’s date and time displayed in the web panel page. ...
2-4 Power Control Monitor Configuration You can set up each individual power outlet on the switch accordinly with advanced features by clicking on the【Monitor】 tab from the Web control panel as illustrated in the following paragraph. 2-4-1 Power Switch Setup Click the「Set」button located on the top corner of each power outlet icon to set up set up the startup/shut down point with or without delay period.
2-4-2 Power Switch Operation Move your mouse over to this section and left click on the mouse button twice to manually open or close any particular outputlet’s power from the web control panel at your networked computer terminal. Move your mouse over to each power outlet button icon and left click on the mouse button twice to manually open or close any particular outputlet’s power from the web control panel at your networked computer terminal.
Page 18
3. Advanced Setup This chapter is mainly to explain the advanced operation in the web control panel. You may learn about all the advanced features and functions of Power Monitor, System Setup, Account Management, Time Synchronization, Event Record and Firmware Upgrade.
Start Delay Time:This column allows users to have each power device connected start up at different moments instead of all starting up at the same time. Each power outlet can be programmed to wait for the specified time period in seconds or minutes before startup.
Page 20
Equipment Network Address:Enter the IP address of the network equipment. PING Interval Time:Set the time Interval to execute the PING function on the network equipment. Detect Times:If a device fails to respond to a ping continuously and exceeds the preset trial times, the switch will send the warning message or email to the qualified personnel.
Page 21
3-2 System Setup In this section you may learn to set up web/network, email server and message services. 3-2-1 Network Setup IP network information data entry: Address:Assign the Network IP address for the power switch. Subnet Mask:Set up the subnet mask info of this equipment. Gateway:Set up the gateway port of this equipment.
Page 22
3-2-2 Email Server Setup When there is a triggered warning from the setup of this power switch, this device will send out an alert message to the preset email accounts. SMTP Server Address:Enter your SMTP server address here. SMTP Port:Enter your SMTP port number here. The preset value is 25. Sender Mail Address:This section will be displayed in where the alert email is sent from.
3-2-3 Message Server Setup When there is a warning, setup the warning message data in the Message Server. Server Address: Enter the SMS message server’s IP address here so the SMS text message can be transmitted to the SMS server when the warning event is triggered by the preset value.
3-2-4 SNMP Setup System Name:Display System Name on the program of SNMP Client. System Contact:Display System Contact Person on the program of SNMP Client. System Location:Display System Site on the program of SNMP Client. Receiver IP Address:When something happens to Trap and it is IP site which will be sent to Trap.
When this intelligent remote power switch is daisy chained with other phone devices like fax machine or answering machine, you can set the lower priority on this power switch by assigning more rings needed so to let users or other phone devices to attend the phone call first.
Page 26
Mail Address:Enter contact email address here when the alert message needs to be transmitted by email service. Administrator or system manager of this power switch can also assign the access levels for each user account. For example manager can assign user A to access either all 2 power outlets on the switch or just a particular one outlet is allowed for access.
Page 27
3-4 Time Simultaneity Equipment Date:The system date of the remote power switch. Equipment Time:The system time of the remote power switch. : If you choose this item, the equipment time of the remote power switch will Sync with PC be the same as the computer system. Date:...
Page 28
3-5 Event Log In this section, you may check the log of all the power operations and warning events in the recent 7 days. You can find out what power action occurred on what outlet and at what time by access remotely or locally from the web panel. At the same time, if the power switch can not operated normally, it will produce warning case.
Page 29
3-6 Firmware Upgrade You may download the newest Firmware in the website of the supplier to proceed SmartPower Upgrade. 3-6-1 Firmware Upgrade Steps of Upgrade are as below: Step 1: Press「BROWSE」button. Step 2:Select the catalogue of Firmware Renew File and press 「OPEN」 after selecting the file.
Page 30
If the file you choose is not Firmware file or it is old-fashioned version, you can’t do the action of SmartPower Upgrading. 3-6-2 Download / Reset Configuration The steps of Store Setup File are as below: Step 1: Press「Download」button. Step 2: Store Setup File in the catalogue you appointed.
Page 31
Step 2:Select the catalogue of Setup File and press 「OPEN」after selecting. Step3:By means of Re-set Setup File Function, when you press 「Upload」button, it will be displayed according to the following state: SmartPower will reboot automatically, and will finish Setup File Reset.
Page 32
If the file you chose is not SETUP File, you can’t process the action of SmartPower Setup File Reset. - 31 -...
Page 33
Attachment (A): How to reset this remote power switch to the initial default value ? Answer: In case that user forgot the password for the web network access to the power switch, user can always reset the power switch back to manufacturer’s default setting. Locate the “RESET”...