Summary of Contents for SmartPower OFFICE Plus Series
Page 1
Uninterruptible Power Supply OFFICE Plus Series 420VA - 850VA USER'S GUIDE Models: OF420UPlus-T OF650UPlus-T OF850UPlus-T...
Page 2
Important Safety Instructions Save These Instructions This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate.
Important Safety Instructions Save These Instructions NOTICE!!! The output of the Office 420 is not sinusoidal. It has a total harmonic distortion of 61% and a maximum single harmonic distortion of 46.6%. The output of the Office 650 is not sinusoidal. It has a total harmonic distortion of 46% and a maximum single harmonic distortion of 33%.
System Description 1. Power On/Off Switch 2. Green LED: On AC Line Mode Yellow LED: Battery Mode Red LED: Fault 3. Battery power Plus Power Conditioning TBF™ Receptacles with battery power plus power conditioning (TBF™) for critical devices that need to stay on when power goes out. 4.
Troubleshooting If the UPS failed to operate properly, please review the following: Symptom Possible Cause Solution The outlets stop Circuit breaker has Turn the UPS off and providing power to tripped due to an unplug at least one equipment. Circuit overload piece of equipment.
Page 6
Installation and Operation Installing the Office Series UPS is as easy as following the steps shown. Be aware that the Power Switch must be kept in the "ON" position and all equipment must be plugged into the "Battery Power Supplied" receptacles. Otherwise the UPS will be disabled and your equipment will not be protected during a power failure.
Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8-10 hours with no load (no electrical devices such as computers, monitors, etc.) connected.
Page 8
USB Connection with Network Protection To allow for unattended system shutdown for your operating system, connect the USB cable as shown in the diagram below. To protect the Network connection, plug incoming Network line into the "in" socket at the rear panel of the Office Plus UPS. Use provided CAT5 Network cable and plug one end to the "Out"...
Wall mounting instructions The wall mount key holes in the back of the UPS let you mount your Office Plus UPS on a wall or other surface. Make sure to place the unit where monitoring lights can be observed. KEY HOLES WALL MOUNT - RETAIL APPLICATION Turn On/Off Press power switch to turn on the...
DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. Battery Replacement CAUTION: Battery replacement should be performed by qualified service personnel.
Specifications OF420UPlus-T OF650UPlus-T OF850UPlus-T MODEL OUTPUT Capacity VA / W 420 / 210 650 / 330 850 / 450 Voltage (on battery) Simulated sine wave at 120VAC ±10% Frequency (on battery) 50/60Hz ±1% 4 milli seconds typical Transfer Time INPUT Voltage Range 90~140VAC Frequency...
LIMITED PRODUCT WARRANTY We warrant this product to be free from defects in material and workman- ship for 2 years. The battery has a 2 year warranty. If a product proves to be defective in material or workmanship during the warranty period, we will at our sole option repair or replace the product with a like product.