  • Page 1: Power Supply

    Uninterruptible Power Supply OFFICE Series 400VA / 600VA USER'S GUIDE Models: OF400-TBF, OF400USB-TBF, OF600-TBF, OF600USB-TBF...
  • Page 2 Important Safety Instructions Save These Instructions CAUTION!!! Please read the following information carefully and save this manual for future reference. Ignoring these safety warnings may endanger your life or health, as well as the function of the equipment and safety of your data.
  • Page 3 Important Safety Instructions Save These Instructions NOTICE!!! The output of the Office 400 is not sinusoidal. It has a total harmonic distortion of 61% and a maximum single harmonic distortion of 46.6%. The output of the Office 600 is not sinusoidal. It has a total harmonic distortion of 46% and a maximum single harmonic distortion of 33%.
  • Page 4: System Description

    System Description Top View: 1. Power On/Off Switch 2. Green LED: On AC Line Mode 3. Amber LED: Battery Mode 4. Red LED: Fault 5. Power conditioning (TBF™) only receptacle 6. Battery power plus power conditioning (TBF™) receptacles REAR VIEW OF400-OF600 Rear View: 7.
  • Page 5: Troubleshooting

    Troubleshooting If the UPS failed to operate properly, please review the following: Symptom Possible Cause Solution Green LED is "ON", 1. UPS is not connected 1. Connect the UPS but audible alarm is properly to the main power. according to the installa- heard intermittently.
  • Page 6: Installation And Operation

    Installation and Operation Installing the Office Series UPS is as easy as following the steps shown. Be aware that the Power Switch must be kept in the "ON" position and all equipment must be plugged into the "Battery Power Supplied" receptacles. Otherwise the UPS will be disabled and your equipment will not be protected during a power failure.
  • Page 7: Computer Connection

    Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8-10 hours with no load (no electrical devices such as computers, monitors, etc.) connected.
  • Page 8 USB Connection with Network Protection (OF-USB models only) To allow for unattended system shutdown for your operating system, connect the USB cable as shown in the diagram below. To protect the Network connection, plug incoming Network line into the "in" socket at the rear panel of the Office-USB Series UPS.
  • Page 9: Bracket Installation

    Installation instructions for wall-mountable models The "EIP" (Easy Installation Plate) lets you mount your Office UPS without the use of rulers, making the installation a snap. RETAIL APPLICATION Bracket Installation To mount your Office UPS to a wall or "EIP" other surface, first, install the provided "EIP"...
  • Page 10: Dc Start Function

    DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. Green Power Function All Office Series UPS are equipped with Green Power Function. If no load connects to the UPS, it will automatically shut down in 5 minutes for energy saving during power failure.
  • Page 11 Free Software Download SmartPower Systems provides a complete line of software solutions for standalone and networked computers, including SNMP POWER MANAGEMENT SOFTWARE support. FEATURES • Automatic Save and Shutdown for unattended PCs • Reboot/Shutdown scheduling • Self test scheduling • Power condition analysis •...
  • Page 12 Specifications - 400VA/600VA MODEL OF400-TBF OF400USB-TBF OF600-TBF OF600USB-TBF OUTPUT Capacity VA / W 400 / 200 600 / 300 Voltage (on battery) 120VAC ±10% Simulated sinewave Frequency (on battery) 50/60Hz ±1Hz 4 milli seconds, including detection time Transfer Time INPUT...
  • Page 13: Limited Product Warranty

    LIMITED PRODUCT WARRANTY We warrant this product to be free from defects in material and workman- ship for 2 years. The battery has a 2 year warranty. If a product proves to be defective in material or workmanship during the warranty period, we will at our sole option repair or replace the product with a like product.