Astria MagniFlame OD24NM Installation And Operation Instructions Manual

Advertisement

P/N 126780-01 Rev. a 1/2014
P126780-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
DANGER
WARNING: Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other
appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Read the installation, operating and maintenance instructions thoroughly before install-
ing or servicing this equipment.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
PFS
WHEN USED AS AN OUTDOOR APPLIANCE
CARBON MONOXIDE WARNING
This appliance can produce
carbon monoxide which has
no odor.
Using it in an enclosed
space can kill you.
Never use this appliance in
an enclosed space such as
a camper, tent, car or home.
WHEN USED AS INDOOR VENTED APPLIANCE
Installation and Operation Instructions
Astria
Vented Gas Log and Burner Set
TM
Models
MagniFlame
MagniFlame
®
OD24NM
US
SouthernComfort24
SouthernComfort30
WARNING: For Outdoor Use Only.
DANGER
IF YOU SMELL GAS:
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appli-
ance and immediately call your gas supplier
or fire department.
MagniFlame
OD24PM
OD30NM
SouthernComfort36
MagniFlame
OD30PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MagniFlame OD24NM and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria MagniFlame OD24NM

  • Page 1 Installation and Operation Instructions Astria Vented Gas Log and Burner Set P/N 126780-01 Rev. a 1/2014 Models MagniFlame MagniFlame MagniFlame MagniFlame ® OD24NM OD24PM OD30NM OD30PM SouthernComfort24 SouthernComfort30 SouthernComfort36 P126780-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ..................2 Specifications ..............18 Product Identification ............3 Wiring Diagram ..............18 Local Codes.................4 Troubleshooting ..............19 Optional Remote Control Accessories ........4 Accessories ...............23 Unpacking................4 Parts ..................24 Product Features ..............4 Service Hints ..............27 Installation ................4 Technical Service...............27 Operation ................15 Replacement Parts ............27 Inspecting Burners.............16 Warranty ................28 Cleaning and Maintenance ..........16...
  • Page 3: Product Identification

    SAFETY Continued 1. This appliance is only for use with the type of gas indicated 15.This appliances must not be connected to any external on the rating plate. This appliance is not convertible for use electrical source. with other gases. 16.Operating appliance above elevations of 4,500 feet may 2.
  • Page 4: Local Codes

    WARNING: Maintain the minimum clear- ELECTRONIC IGNITION SYSTEM ances. If you can, provide greater clearances This appliance has an electronic ignitor to light appliance fuel supply. from floor, ceiling and adjoining wall. www.Astria.US.com 126780-01A...
  • Page 5 IMPORTANT: If you cannot meet these minimum clearances, you must operate appliance with chimney flue damper open. *Minimum 16" from Side Wall Go to Installing Damper Clamp Accessory for Vented Opera- tion, page 7. Figure 2 - Minimum Clearance for Combustible to Wall www.Astria.US.com 126780-01A...
  • Page 6 15" 18" 20" Min. Top of Fireplace Hearth Opening Combustible Hood (GA6050 Distances to or GA6053) Material Underside of Mantel 5" Min. Figure 7 - Minimum Fireplace Clearances Above Figure 5 - Minimum Mantel Clearances When Using Combustible Flooring Hood www.Astria.US.com 126780-01A...
  • Page 7 (Install if allowed by Figure 8 - Attaching Damper Clamp local codes) Elbow, 1/2 NPT x WARNING: DO NOT INSTALL IN 3/8 Flare SLEEPING ROOM OF MOBILE HOMES. Gas Control Figure 9 - Attaching Flexible Gas Hose to Appliance Gas Regulator www.Astria.US.com 126780-01A...
  • Page 8 • approved flexible gas line with gas connector (if allowed by Figure 11 - External Regulator With Vent Pointing Down local codes) (not provided * An equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connection. Purchase the www.Astria.US.com 126780-01A...
  • Page 9 1. Disconnect appliance with its appliance main gas valve Location (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage Figure 14- Checking Gas Joints (Propane/LP Only) appliance regulator. www.Astria.US.com 126780-01A...
  • Page 10 Installing Batteries for Remote Receiver and Hand Held Terminal on Remote Control Switch Follow instructions accompanying remote control accesory to install batteries. Note: Only use alkaline batteries. To AUTO Control Valve Terminal on Switch Figure 16 - Connecting Wires www.Astria.US.com 126780-01A...
  • Page 11 Figure 18 - Installing Right Front Log so, reposition logs according to log installation instructions in this manual. Flames contacting logs will create soot. Round Tube Burner Grate Finger Figure 18A - Installing Right Front Log, Top View www.Astria.US.com 126780-01A...
  • Page 12 D-017 or D025) edge of the pan. Back Left Log (D-060, Flat Part of Log D-018 or D026) Log Notch Burner Tube Grate Fingers Figure 20 - Installing Front Left Log Figure 19 - Installing Back Left Log www.Astria.US.com 126780-01A...
  • Page 13 See figures for reference. Log Notch Square Peg Right Front Log Middle Split Log (D-063, D-021 or D028) Figure 21 - Installing Charred Log Figure 22 - Installing Middle Split Log (D-021) www.Astria.US.com 126780-01A...
  • Page 14 Place lava rock around the base of the burner assembly on the fireplace floor to simulate an ash bed. Do not place lava rock or any other material on the burner. Middle Split Log Figure 24 - Installing Front Top Log www.Astria.US.com 126780-01A...
  • Page 15: Operation

    After 30 seconds, release control knob. • If control knob does not pop out when released, turn off gas supply and contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. www.Astria.US.com 126780-01A...
  • Page 16: Inspecting Burners

    Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle. Figure 28 - Correct Burner Flame Pattern 5. Blow air into the primary air holes on the injector holder. www.Astria.US.com 126780-01A...
  • Page 17 Figure 30 - Injector Holder On Outlet Burner Tube necessary by a qualified service person. Thermopile 3/8" to 1/2" Pilot Burner 1/8" Thermocouple Piezo Ignitor Figure 31 - Pilot Inlet Air Hole (Your pilot may vary from pilot shown) www.Astria.US.com 126780-01A...
  • Page 18: Specifications

    Max - 10.5" W.C., Min* - 5" W.C. Max - 14" W.C., Min* - 11" W.C. *For purpose of input adjustment *For purpose of input adjustment WIRING DIAGRAM (REMOTE READY MODELS) To Thermopile To OFF Terminal on Switch To AUTO Terminal on Switch www.Astria.US.com 126780-01A...
  • Page 19: Troubleshooting

    LP only) 5. Contact local propane/LP gas 6. ODS/pilot is clogged company 6. Clean ODS/pilot (see Cleaning and Maintenance, page 16) or 7. Gas regulator setting is not cor- replace ODS/pilot assembly rect 7. Replace gas regulator www.Astria.US.com 126780-01A...
  • Page 20 Burner backfiring during combustion 1. Burner orifice is clogged or dam- 1. Clean burner (see Cleaning and aged Maintenance, page 16) or replace burner orifice 2. Damaged burner 2. Replace damaged burner 3. Gas regulator defective 3. Replace gas regulator www.Astria.US.com 126780-01A...
  • Page 21 If noise is excessive, contact or shut off qualified service person 2. Wire connection loose or wire 2. Check wiring connections (see broken wiring diagram, page 18). Re- place wire harness if necessary. www.Astria.US.com 126780-01A...
  • Page 22 Gas odor during combustion valve and burner 1. Take apart gas tubing and remove 2. Gas leak. See Warning state- foreign matter ment at top of page 2. Locate and correct all leaks (see Checking Gas Connections, page www.Astria.US.com 126780-01A...
  • Page 23: Accessories

    Fits openings 28" to 48" wide. RECEIVER AND HAND-HELD REMOTE CONTROL KIT - MRC (REMOTE READY MODELS ONLY) For all models. Allows the fireplace to be turned on and off by using a hand-held remote control. www.Astria.US.com 126780-01A...
  • Page 24: Parts

    PARTS REMOTE-READY CONTROL MODELS MagniFlameOD24NM, MagniFlameOD24PM, MagniFlameOD30NM, MagniFlameOD30PM www.Astria.US.com 126780-01A...
  • Page 25 This list contains replaceable parts used in your appliance. When ordering parts, follow the instructions listed under Replace- ment Parts below PARTS AVAILABLE, NOT SHOWN - ALL MODELS 100639-12 Caution Decal 101137-02 Hardware Kit GA6060 Lava Rock 120466-01 Flextube with Fitting 099998-01 Fan Switch www.Astria.US.com 126780-01A...
  • Page 26 Log, Back Top 125538-01 None 125538-01 None 125538-01 None Log Switch Each log includes a reference number. The first number indicates the order it is placed on the burner assembly. The next two numbers indicate the set size. www.Astria.US.com 126780-01A...
  • Page 27: Service Hints

    You may have further questions about installation, operation or troubleshooting. If so, contact INNOVATIVE HEARTH PRODUCTS at 1-800-655-2008. When calling please have your model and serial numbers of your appliance ready. You can also visit our web site at www.IHP.US.com. www.Astria.US.com 126780-01A...
  • Page 28: Warranty

    THE WARRANTY Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Astria™ brand Gas Log Set or Outdoor Gas Fire Pit ("Product") to be free from defects in materials and workmanship at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original instal- lation, IHP will, at its option, repair or replace the covered components.
  • Page 29 KEEP THIS WARRANTY Model (located on product or identification tag) �������������������������������������� Serial No. (located on product or identification tag) ����������������������������������� Date Purchased �������������������������������������������� Keep receipt for warranty verification. www.Astria.US.com 126780-01A...
  • Page 30 NOTES www.Astria.US.com 126780-01A...
  • Page 31 NOTES www.Astria.US.com 126780-01A...
  • Page 32 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126780-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P126780-01...

This manual is also suitable for:

Magniflame od30nmMagniflame od24pmMagniflame od30pm

Table of Contents