Astria Blaze&Glow18EN Installation And Operation Instructions Manual

Unvented (vent-free) gas log heater for use with log sets andesmtn18; andesmtn24; andesmtn30; andesmtn36; bisonmtn18; bisonmtn24; bisonmtn30; redwoodm18; redwoodm24; redwoodm30
Hide thumbs Also See for Blaze&Glow18EN:

Advertisement

Quick Links

P/N 126834-01 REV. B 05/2017
P126834-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases.
WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built
fi replace or in a listed ventless fi rebox enclosure. It is design-certifi ed for these installations in accordance
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fi replace that includes
instructions stating it has not been tested or should not be used with unvented gas logs.
This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on Page 6 of this manual.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
- Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
Installation and Operation Instructions
Unvented (Vent-Free) Gas Log Heater
Models
PFS
®
Blaze&Glow18EN
US
Report No. F09-100
For use with log sets
Blaze&Glow18EP
AndesMtn18
BisonMtn18
BisonMtn24
AndesMtn24
AndesMtn30
BisonMtn30
AndesMtn36
Blaze&Glow24EN
Blaze&Glow24EP
RedWoodM18
RedWoodM24
RedWoodM30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Blaze&Glow18EN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Blaze&Glow18EN

  • Page 1 Installation and Operation Instructions Unvented (Vent-Free) Gas Log Heater Models P/N 126834-01 REV. B 05/2017 ® Blaze&Glow18EN Blaze&Glow18EP Blaze&Glow24EN Blaze&Glow24EP Report No. F09-100 For use with log sets P126834-01 AndesMtn18 BisonMtn18 RedWoodM18 BisonMtn24 RedWoodM24 AndesMtn24 AndesMtn30 BisonMtn30 RedWoodM30 AndesMtn36 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    WARNING: This product contains and/or generates chemicals known DANGER: Carbon monoxide to the state of California to cause poisoning may lead to death! cancer or birth defects or other re- productive harm. Astria.us.com 126834-01B...
  • Page 3 Avoid any drafts that alter burner Solid-fuels shall not be burned in a fl ame patterns. Ceiling fans can fi replace in which an unvented room create drafts that alter burner fl ame heater is installed. patterns. Altered burner patterns can cause sooting. Astria.us.com 126834-01B...
  • Page 4 Any 20. Provide adequate clearances around air glass doors shall be fully opened when the openings. appliance is in operation. If you operate heater with doors closed, heat buildup inside fi replace will cause glass to burst. Astria.us.com 126834-01B...
  • Page 5: Product Identifi Cation

    • A working smoke detector must be installed in the area where vent-free appliances are installed. Seller of unvented propane or natural gas-fi red supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. Astria.us.com 126834-01B...
  • Page 6: Product Features

    The National Fuel Gas Code, ANSI Z223.1/ Combustion and Ventilation. NFPA54 allows two methods for determining All spaces in homes fall into one of the three whether the space in which the heater is being following ventilation classifi cations: Astria.us.com 126834-01B...
  • Page 7 Hr size makes room unconfi ned. If the actual Btu/Hr used is less than the maxi- mum Btu/Hr the space can support, the space is an unconfi ned space. You will need no additional fresh air ventilation. Astria.us.com 126834-01B...
  • Page 8 Figure 3 - Ventilation Air from Outdoors grills or ducts. 12" Ventilation Ventilation Grills Grills Into Into Adjoining Room, Adjoining Option 2 Room, Remove Option 1 Door into Adjoining Room, Option 12" Figure 2 - Ventilation Air from Inside Building Astria.us.com 126834-01B...
  • Page 9: Installation

    Although this is benefi cial, installing closed at time of appliance in- heater in rooms without enough ventilation stallation. air may cause mildew to form from too much moisture. See Air for Combustion and Ventila- tion, Page 6. Astria.us.com 126834-01B...
  • Page 10 12", you must install UL127-listed manufactured fi replace or listed the fi replace hood accessory (24", 30" and vent-free fi rebox. 36" Models Only). See Figure 5 for minimum clearances. Astria.us.com 126834-01B...
  • Page 11 12", you may need the product standard. Follow all hood accessory to defl ect heat away from minimum clearances shown in your mantel shelf. See Figures 5 and 6 and this manual. Figure 7, Page 12, for minimum clearances. Astria.us.com 126834-01B...
  • Page 12 • approved fl exible gas hose and fi ttings (if allowed by local codes) Figure 8 - Minimum Fireplace Clearances • sealant (resistant to propane/LP gas, not If Installed at Floor Level provided) • electric drill with 3/16” masonry drill bit Astria.us.com 126834-01B...
  • Page 13 • equipment shutoff valve • test gauge connection • sediment trap • tee joint • pipe wrench • approved fl exible gas line with gas connec- tor (if allowed by local codes) Figure 11 - Attaching Base to Fireplace Floor Astria.us.com 126834-01B...
  • Page 14 Check your building codes for any special requirements for locating equipment shutoff valve to fi replaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. Astria.us.com 126834-01B...
  • Page 15 fl uid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff Control Valve Location valve to gas supply. Check reconnected fi ttings for leaks. Figure 16 - Checking Gas Joints (Natural Gas Only) Astria.us.com 126834-01B...
  • Page 16 S1 Button Figure 19 - Touch Pad Control Cable Connect Battery Plug Here Figure 20 - Connecting end of Touch Pad Cable Figure 17 - Control Module Astria.us.com 126834-01B...
  • Page 17 Front Left Chassis Rear Log Left Log Support Bracket Right Log Support Bracket Grate Prongs Bottom Log Front Right Front of Chassis Base Assembly Right Log Figure 22- Installing Log Support Brackets Figure 23 - Installing Log Set Astria.us.com 126834-01B...
  • Page 18 2. The log must sit fl at on the black sheet metal and behind the left metal tab as shown in Figure 28. Astria.us.com 126834-01B...
  • Page 19 The recessed areas are painted yellow. Front Right Log Figure 31 - Installing Log Description RedWoodM18 RedWoodM24 RedWoodM30 QTY. Front Left Log Front Right Log Rear Log Top Left Log Top Right Log Sm. Top Rt. Log Astria.us.com 126834-01B...
  • Page 20 fl ame from the ember pan does not touch the ember bed log. Ramp Log Metal Figure 42 - Installing Fiber Ramp Log Astria.us.com 126834-01B...
  • Page 21 The right middle log should have a recess area that fi ts around the ramp log as shown in Figure 47. Right Middle Figure 49 - Installing Rear Log Figure 47 - Installing Right Middle Log Astria.us.com 126834-01B...
  • Page 22 (see Figure 52). left, "2" in the center, and "3" on the right. These numbers are embossed on the back of each piece for identifi cation purposes. Please note that Blaze&Glow18 burner systems do not include ember chunks. Astria.us.com 126834-01B...
  • Page 23 Flat Front Burner Ember Chunk #3 Figure 53 - Ember Chunk Placement Blaze&Glow24 Series Flat Front Burner Ember Material Figure 54 - Platinum Bright Embers Glowing Embers (rockwool) Figure 55 - Placement of Glowing embers (shown with Platinum Bright Embers) Astria.us.com 126834-01B...
  • Page 24: Operation

    TO TURN OFF GAS causing property damage, per- TO APPLIANCE sonal injury or loss of life. 1. Once you have activated the screen press the MODE Zone or MODE/SET Button until you see OFF. 2. Close equipment shutoff valve. Astria.us.com 126834-01B...
  • Page 25 ROOM TEMP Zone ° SET TEMP Zone S M T W T F S TIME/PROG Zone PROGRAM FLAME Zone CHANNEL PROG Zone CHANNEL UNLOCK Zone MODE/SET Button DOWN Button UP Button MODE/SET Figure 56 - Touch-Screen LCD and Button Layout Astria.us.com 126834-01B...
  • Page 26 The modes may be cycled in the order above simultaneously to change between by touching the MODE Zone or pressing the degrees F and C. MODE/SET Button. • SET TEMP: While in THERMOSTAT mode, press the UP or DOWN Button Astria.us.com 126834-01B...
  • Page 27 • TIME/PROG Zone: Current day indicator displayed as 12:00am. and current time is displayed • Day/Time Setup: • FLAME Zone: Blank 1. Press and hold the MODE Zone for 5 • THERMOSTAT ON LCD Displays: seconds to enter Day/Time Setup. Astria.us.com 126834-01B...
  • Page 28 (Intermittent Pilot Ignition (IPI)/ in MODE Zone) or PROGRAM and ON Spark-to-Pilot not allowed). (ON display in MODE Zone) will fl ash • Pilot fl ame will remain ON when Main 3-times (0.5-seconds OFF, 0.5-seconds Flame Cycles ON and OFF. Astria.us.com 126834-01B...
  • Page 29 MANUAL OFF mode and send a MANUAL OFF command to the control module. If the user turns the control back Connect Battery Plug Here ON and the room temperature is still Figure 17 - Control Module Astria.us.com 126834-01B...
  • Page 30: Inspecting Burners

    2. To decrease the fl ame level, press the down button ( ). A beep and a fl ash of the LED indicate that the system has accepted the order, and the fl ame will decrease instantly (see Figure 59). Astria.us.com 126834-01B...
  • Page 31: Cleaning And Maintenance

    • see Troubleshooting, Page 34 more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc. WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage. Astria.us.com 126834-01B...
  • Page 32 fl ame present. Some burner fl ame holes may become blocked by debris or rust, with no fl ame present. If so, turn off heater and let cool. Remove blockage, blocked burner fl ame holes will create soot. Astria.us.com 126834-01B...
  • Page 33: Wiring Diagram

    • Manifold Pressure: 4.5" W.C. • Inlet Gas Pressure (in. of water): • Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C. Max - 10.5" W.C., Min* - 5" W.C. *For purpose of input adjustment Astria.us.com 126834-01B...
  • Page 34: Troubleshooting

    If this is the case, disconnect, align, and reconnect to the module. 5. Remote not communicating with 5. (The remote communicates with control module the module periodically. It doesn't communicate with the module continuously to conserve battery power). Astria.us.com 126834-01B...
  • Page 35: Troubleshooting

    16. The control module sounds 2 16. Connect the wiring harness at cycles of 5 beeps. The wiring the control module. Replace assembly from the control valve the valve assembly if all other is disconnected or broken. cause/remedies fail to correct his problem. Astria.us.com 126834-01B...
  • Page 36 6. Connect valve cable correctly or broken. 7. ODS pilot is clogged 7. Clean ods pilot (see Cleaning and Maintenance , Page 31) or replace ods pilot assembly. 8. Gas regulator setting is not 8. Replace gas regulator correct Astria.us.com 126834-01B...
  • Page 37 1. Short in touch pad wiring. 1. Replace touch pad and wiring ing 6 seconds then sounds 5 beeps. harness. Low battery power in remote. 1. Batteries are weak. LOW BAT- 1. Replace batteries in remote. TERY is shown in remote dis- play. Astria.us.com 126834-01B...
  • Page 38 Burner system lights or shuts off 1. More than one burner system 1. Follow Pairing instructions on without touching the remote. is present and operating on the Page 29 to re-pair remote to same frequency. control module. Astria.us.com 126834-01B...
  • Page 39 Heater produces a clicking/ticking 1. Metal expanding while heating 1. This is normal with most heaters. noise just after burners are lit or or contracting while cooling If noise is excessive, contact shut off qualifi ed service person Astria.us.com 126834-01B...
  • Page 40 Log set cycles to pilot, but room tem- 1. Optional Hand-held remote 1. Move hand-held remote control perature drops to a lower than ideal control is too close to heater unit farther away from the heater level before log set comes back on Astria.us.com 126834-01B...
  • Page 41: Replacement Parts

    EMBER KITS your local dealer. If they can not supply these (rockwool) Platinum Embers accessories, contact IHP at Astria.us.com for Cat. No J6208 Cat. No J6207 referral information. You can also write to the address listed on the back page of this VENT-FREE FIREBOXES manual.
  • Page 42 ACCESSORIES Continued LOG SCRAPS / FLOOR MEDIA KIT-1 LOG SCRAPS / FLOOR MEDIA KIT-2 Cat. No. F0250, Model VTA-LS5-1 Cat. No. F0251, Model VTA-LS5-2 Astria.us.com 126834-01B...
  • Page 43 ACCESSORIES Continued DECORATIVE ASH BED / CONTROL COVER KIT (SIX PACK) Cat. No. F1759, Model CDABKA-6 GAS APPLIANCE INSTALLATION KIT Cat. No. F0249, Model CIKA DECORATIVE ASH BED / CONTROL COVER KIT Cat. No. F0246, Model CDABKA Astria.us.com 126834-01B...
  • Page 44: Parts

    J6587 Screw, Min. Rate • J6580 Supply, Battery Power • • • • J6674 Touch Pad Manual Control • • • • J6675 Touch Pad Wire Harness • • • • ** Not a fi eld replaceable part. Astria.us.com 126834-01B...
  • Page 45 Injector (.053) Middle Burner • J3679 Injector (.047) Middle Burner • F2933 Injector (.085) Middle Burner • K2014 Control Module Heat Shield • • • • J5918 Aluminum Spacers • • • • J6508 Pilot Shield • • Astria.us.com 126834-01B...
  • Page 46 AndesMtn18 AndesMtn24 AndesMtn30 J5708 J5714 J5720 Front Right Log J5707 J5713 J5719 Front Left Log J5705 J6554 J6554 Middle Right Log J5706 J5712 J5718 Middle Left Log J5704 J5716 J5716 Bottom Log (Remote) J5709 J5715 J5721 Rear Log Astria.us.com 126834-01B...
  • Page 47 Middle Right Log J5718 Middle Left Log J5722 Front Left Log J5723 Front Right Log J5724 Back Log J5725 Left Small Front Log J5726 Right Small Front Log J5727 Left Control Cover Log J5728 Right Control Cover Log Astria.us.com 126834-01B...
  • Page 48 D-004 J6186 D-011 Middle Left Log J6192 NONE J6193 NONE J6193 NONE Ramp Log J6189 D-014 J6178 D-003 J6184 D-009 Rear Log J6181 D-006 J6181 D-006 J6181 D-006 Top Log J5669 NONE J5669 NONE J5669 NONE Log Switch Astria.us.com 126834-01B...
  • Page 49 D-043 Log, Rear J6637 D-046 J6637 D-046 J6637 D-046 Log, Left Top J6638 D-070 J6650 D-044 J6650 D-044 Log, Middle Crossover J6639 D-071 J6651 D-045 J6651 D-045 Log, Top Rear J5669 NONE J5669 NONE J5669 NONE Log, LBG-BM Switch Astria.us.com 126834-01B...
  • Page 50: Blaze&Glow Log Sets

    30" Andes Mountain Log Set Fiber F0147 AndesMtn36 36" Andes Mountain Log Set Fiber F0148 RedWoodM18 18" Red Wood Mountain™ Log Set Refractory F0149 RedWoodM24 24" Red Wood Mountain Log Set Refractory F0150 RedWoodM30 30" Red Wood Mountain Log Set Refractory Astria.us.com 126834-01B...
  • Page 51: Warranty

    IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.
  • Page 52 Astria.us.com Record the following important information about your appliance: Appliance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time, without notice, in design, materials, specifi...

This manual is also suitable for:

Blaze&glow24enBlaze&glow18epBlaze&glow24ep

Table of Contents