INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built
fireplace or in a listed ventless firebox enclosure. It is design-certified for these installations in accordance
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fireplace that includes
instructions stating it has not been tested or should not be used with unvented gas logs.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on page 6 of this manual.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Astria™ Unvented (Vent-Free) Gas Log Heater
Models
Montebello18NE
Montebello18PE
Montebello24NE
Montebello24PE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Montebello18NE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Montebello18NE

  • Page 1 Installation and Operation Instructions Astria™ Unvented (Vent-Free) Gas Log Heater P/N 126813-01 Rev. A 02/2014 Models Montebello18NE Montebello18PE Montebello24NE Montebello24PE P126813-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    * Aftermarket: Completion of sale, not for that includes instructions purpose of resale, from the manufacturer stating it has not been test- ed or should not be used with unvented gas logs. www.Astria.US.com 126813-01A...
  • Page 3 Keep the appliance area clear and WARNING: Do not use a free from combustible materials, blower insert, heat exchanger gasoline and other flammable va- insert or other accessory not ap- pors and liquids. proved for use with this heater. www.Astria.US.com 126813-01A...
  • Page 4: Unpacking

    3. Check heater for any shipping damage. If heater is damaged call INNOVATIVE information. HEARTH PRODUCTS at 1-800-655-2008 for replacement parts before returning to 1. Remove log set assembly from carton. dealer. Note: Do not pick up assembly by logs. www.Astria.US.com 126813-01A...
  • Page 5: Product Identification

    New materials, increased insulation cold air out and the warm air in. During heating and new construction methods help reduce heat months, home owners want their homes as loss in homes. Home owners weather strip and airtight as possible. www.Astria.US.com 126813-01A...
  • Page 6 * Do not include direct-vent gas appliances. Confined and Unconfined Space Direct-vent draws combustion air from the The National Fuel Gas Code, ANSI Z223.1/ outdoors and vents to the outdoors. NFPA 54 defines a confined space as a space www.Astria.US.com 126813-01A...
  • Page 7: Ventilation Air

    Inlet Air ceiling and one within 12" of the floor on the Crawl Space wall connecting the two spaces (see options Figure 3 - Ventilation Air from Outdoors 1 and 2, Figure 2). You can also remove door www.Astria.US.com 126813-01A...
  • Page 8: Installation

    LP) for your unit. If your gas supply is not cor- Any outside air ducts and/or ash rect, do not install heater. Call dealer where dumps in the fireplace shall be you bought heater for proper type heater. permanently closed at time of appliance installation. www.Astria.US.com 126813-01A...
  • Page 9 See Figures 5, 6 of the fireplace cabinet (see Figure 4). and 7, page 10, for minimum clearances. Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials. www.Astria.US.com 126813-01A...
  • Page 10 Underside 8" of Mantel Shelf 6" 2½" Minimum Noncombustible Material 8" 12" 15" 18" 20" Min. Top of Hood Fireplace Distances to (GA6050 or Opening Underside of GA6053) Mantel Figure 7 - Minimum Mantel Clearances When Using Hood www.Astria.US.com 126813-01A...
  • Page 11: Safety Information

    5" above the top surface tached to the valve by a velcro strap. This module of combustible flooring including tile and needs to remain where installed. If removed and carpet (see Figure 9). wires cross, this can cause the remote to fail. www.Astria.US.com 126813-01A...
  • Page 12 Pointing heater and propane/LP supply. Down WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as Figure 11 - External Regulator With Vent wellhead gas. Pointing Down www.Astria.US.com 126813-01A...
  • Page 13 See Accessories, opening propane/LP supply tank valve page 25. for propane/LP gas or opening main gas ** Minimum inlet pressure for purpose of input valve located on or near gas meter for adjustment. natural gas or using compressed air. www.Astria.US.com 126813-01A...
  • Page 14 Additional glowing effect can be achieved by fraying edges of ember material. Equipment Shutoff Valve Propane/LP Supply Tank Place Glowing Embers on Burner Ports Control Valve Location Figure 16 - Placement of Embers Figure 15 - Checking Gas Joints for Propane/LP Gas www.Astria.US.com 126813-01A...
  • Page 15: Operation

    Immediately on the floor. call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. www.Astria.US.com 126813-01A...
  • Page 16 1. If you on the remote handset in the following 20 sec., don’t smell gas, go to the next step. the receiver learns the new code. 5. Make sure ON/OFF switch is in "–" (ON) position. www.Astria.US.com 126813-01A...
  • Page 17 Press OFF button on remote control to switch off main gas and pilot gas. Shutting Off Burner Only (pilot stays lit) STAND Press to decrease the flame height and shut off main burner. Figure 18 - Control Panel for Hand-Held Remote www.Astria.US.com 126813-01A...
  • Page 18 TO TURN GAS OFF TO APPLIANCE Press OFF button on remote control to switch off main gas and pilot gas or manually turn Motor knob clockwise to the "O" OFF Piezo Ignitor position. Microswitch ON/OFF Switch Figure 19 - Control Valve www.Astria.US.com 126813-01A...
  • Page 19: Inspecting Burners

    Figure 21 - Correct Pilot Flame Pattern (Natural Gas Pilot Shown) Thermocouple Figure 23 - Correct Burner Flame Pattern Orange Flames Figure 22 - Incorrect Pilot Flame Pattern (Natural Gas Pilot Shown) Figure 24 - Incorrect Burner Flame Pattern www.Astria.US.com 126813-01A...
  • Page 20: Cleaning And Maintenance

    Injector Inlet Opening front burner. Figure 26 - Injector Holder on Front 1. Remove two screws from back of unit Burner Tube that attach main log assembly to base assembly (see Figure 25). www.Astria.US.com 126813-01A...
  • Page 21: Troubleshooting

    2. Wire disconnected from gas 2. Reconnect leads (see Wir- control ing Diagram, page 24) 3. Burner orifice(s) clogged 3. Clean burner (see Cleaning and Maintenance, page 20) or replace burner orifice(s) 4. Bad module 4. Replace module www.Astria.US.com 126813-01A...
  • Page 22 1. Refer to Air for Combustion 1. Not enough combustion/ Moisture/condensation no- and Ventilation require- ventilation air ticed on windows ments (page 5) www.Astria.US.com 126813-01A...
  • Page 23 1. Foreign matter between 1. Take apart gas tubing and control valve and burner remove foreign matter 2. Gas leak. See Warning 2. Locate and correct all leaks statement at top of page (see Checking Gas Con- nections, page 13) www.Astria.US.com 126813-01A...
  • Page 24: Wiring Diagram

    ON/OFF Switch (Optional) Thermocurrent Interrupter Block 8 Wire Connecting Cable Thermocurrent Cable #2 or ON/OFF Switch Soldered Cable Thermocurrent Thermocouple Cable #1 Antenna Ignition Cable SPARK Receiver SPARK ON/OFF Switch Pilot 4 AA Batteries Battery Compartment Thermocurrent Interrupter Block www.Astria.US.com 126813-01A...
  • Page 25: Replacement Parts

    FIREPLACE HOOD Black - GA6050 Antique Brass - GA6053 For all models. Helps deflect heat away from mantel or wall above fireplace. Fits openings 28" to 48" wide. www.Astria.US.com 126813-01A...
  • Page 26: Parts

    PARTS MONTEBELLO18NE, MONTEBELLO18PE, MONTEBELLO24NE, AND MONTEBELLO24PE www.Astria.US.com 126813-01A...
  • Page 27 PARTS This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual. PART NUMBER DESCRIPTION QTY. Montebello18NE Montebello18PE Montebello24NE Montebello24PE 116950-01 116950-01 116805-01 116805-01 Base 116853-02...
  • Page 28: Warranty

    THE WARRANTY Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Astria™ brand Gas Log Set or Outdoor Gas Fire Pit ("Product") to be free from defects in materials and workmanship at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original instal- lation, IHP will, at its option, repair or replace the covered components.
  • Page 29 WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.Astria.US.com 126813-01A...
  • Page 30 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126813-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P126813-01...