Astria Sheridan18NM Installation And Operation Instructions Manual

Advertisement

Quick Links

P/N 126810-01 Rev. A 02/2014
P-126810-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built
fireplace or in a listed ventless firebox enclosure. It is design-certified for these installations in accordance
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fireplace that includes
instructions stating it has not been tested or should not be used with unvented gas logs.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on page 6 of this manual.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Astria™ Unvented (Vent-Free) Gas Log Heater
Models
Sheridan18NM
Sheridan18PM
Sheridan24NM
Sheridan24PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sheridan18NM and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Sheridan18NM

  • Page 1 Installation and Operation Instructions Astria™ Unvented (Vent-Free) Gas Log Heater P/N 126810-01 Rev. A 02/2014 Models Sheridan18NM Sheridan18PM Sheridan24NM Sheridan24PM P-126810-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ..............2 Cleaning and Maintenance ........ 20 Product Identification ........... 5 Troubleshooting ..........21 Local Codes............5 Specifications ............ 25 Optional Remote Control Accessories ....5 Wiring Diagram ..........25 Unpacking............5 Service Hints ............. 25 Product Features ..........
  • Page 3 SAFETY Continued WARNING: Vent-free products WARNING: This product con- are prohibited for bedroom and tains and/or generates chemicals bathroom installation in the Com- known to the State of California monwealth of Massachusetts. to cause cancer or birth defects or other reproductive harm. WARNING: Do not allow fans IMPORTANT: Read this owner’s to blow directly into the heater.
  • Page 4 100 this heater with glass doors closed. Any lb. capacity (propane/LP units only). glass doors shall be fully opened when 19. Provide adequate clearances around air the appliance is in operation. If you oper- openings. www.Astria.US.com 126810-01A...
  • Page 5: Product Identification

    • wall switch 4. Check heater for any shipping damage. • hand-held ON/OFF remote If heater is damaged call INNOVATIVE See Accessories, page 26. HEARTH PRODUCTS at 1-800-655-2008 for replacement parts before returning to dealer. www.Astria.US.com 126810-01A...
  • Page 6: Product Features

    If your home does not meet all of the VENTILATION three criteria above, proceed to Determin- The following are excerpts from National Fuel ing Fresh-Air Flow For Heater Location, Gas Code, ANSI Z223.1/NFPA 54, Air for page 7. Combustion and Ventilation. www.Astria.US.com 126810-01A...
  • Page 7 Z223.1/NFPA 54, the Internation- Gas water heater* _________ Btu/Hr al Fuel Gas Code, or applicable Gas furnace _________ Btu/Hr local codes. Vented gas heater _________ Btu/Hr Gas fireplace logs _________ Btu/Hr Other gas appliances* + ________ Btu/Hr Total = _________ Btu/Hr www.Astria.US.com 126810-01A...
  • Page 8: Installation

    If not, drafting may cause pilot outage or sooting. Use a WARNING: A qualified ser- heat-resistant sealant. Do not vice person must install heater. seal chimney flue damper. Follow all local codes. www.Astria.US.com 126810-01A...
  • Page 9 Any outside air ducts and/or ash dumps air may cause mildew to form from too much in the fireplace shall be permantly closed moisture. See Air for Combustion and Ventila- at the time of appliance installation. tion, page 6. www.Astria.US.com 126810-01A...
  • Page 10 Go to Install- material is less than 12", you must install the ing Damper Clamp Accessory for Vented fireplace hood accessory (24" Model Only). Operation, page 12. See Figure 5 for minimum clearances. www.Astria.US.com 126810-01A...
  • Page 11: Mantel Clearances

    Min. Models Top of Fireplace Opening Hood (GA6050 Distances to Hearth or GA6053) Underside of Combustible Mantel Material 5" Min. Figure 9 - Minimum Fireplace Clearances Figure 7 - Minimum Mantel Clearances Above Combustible Flooring When Using Hood www.Astria.US.com 126810-01A...
  • Page 12 This could damage heater. Chimney Minimum Permanent Only handle base assembly by Height Flue Opening grates. 6' to 15' 39 sq. inches 15' to 30' 29 sq. inches IMPORTANT: Make sure the heater burners are level. www.Astria.US.com 126810-01A...
  • Page 13 Vent propane/LP fireplace directly Pointing to the propane/LP supply. This Down heater requires an external regu- lator (not supplied). Install the Figure 12 - External Regulator With Vent external regulator between the Pointing Down heater and propane/LP supply. www.Astria.US.com 126810-01A...
  • Page 14 13. requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. www.Astria.US.com 126810-01A...
  • Page 15 16). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once. Open Equipment Shutoff Valve Control Valve Location Figure 16 - Checking Gas Joints Closed (Propane/LP Only) Figure 14 - Equipment Shutoff Valve www.Astria.US.com 126810-01A...
  • Page 16: Operation

    HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running. www.Astria.US.com 126810-01A...
  • Page 17 • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. AUTO Note: If pilot goes out, repeat steps 4 through 8. Flame Adjustment Knob Ignitor Button Figure 17 - Control Knob and Ignitor Button Locations www.Astria.US.com 126810-01A...
  • Page 18 Remote Control Specifications : (See instructions with remote for Batteries removing and installing batteries) Transmitter requires 12V (A-23) and 3V button cell for LCD (both included) Remote receiver requires 4 AA (1.5V) alkaline batteries (included) : 303.875 MHz Operating Frequency www.Astria.US.com 126810-01A...
  • Page 19: Inspecting Burners

    (Your Pilot May Differ from Pilots Shown) Figure 22 - Correct Burner Flame Pattern Pilot Burner Dark Orange Flames Thermocouple Thermocouple Figure 21 - Incorrect Pilot Flame Pattern (Your Pilot May Differ from Pilots Shown) Figure 23 - Incorrect Burner Flame Pattern www.Astria.US.com 126810-01A...
  • Page 20: Cleaning And Maintenance

    Figure 25 - Pilot Air Inlet Hole (Your Pilot holes on injector holder for dust and May Differ from Pilots Shown) dirt (see Figure 24 and 25). 3. Blow air through the ports/slots and holes in the burner. www.Astria.US.com 126810-01A...
  • Page 21: Troubleshooting

    6. C le an ODS/pi l ot (se e 6. ODS/pilot is clogged Cleaning and Maintenance, page 20) or replace ODS/ pilot assembly 7. Gas regulator setting is not 7. Replace gas regulator correct www.Astria.US.com 126810-01A...
  • Page 22 1. Burner orifice is clogged or 1. Clean burner (see Cleaning Burner backfiring during com- damaged and Maintenance, page 20) bustion or replace burner orifice 2. Damaged burner 2. Replace damaged burner 3. Gas regulator defective 3. Replace gas regulator www.Astria.US.com 126810-01A...
  • Page 23 Heater produces a clicking/ 1. Metal expanding while heat- 1. This is normal with most ticking noise just after burners ing or contracting while heaters. If noise is exces- are lit or shut off cooling sive, contact qualified service person www.Astria.US.com 126810-01A...
  • Page 24 1. Foreign matter between 1. Take apart gas tubing and control valve and burner remove foreign matter 2. Gas leak. See Warning 2. Locate and correct all leaks statement at top of page (see Checking Gas Con- nections, page 14) www.Astria.US.com 126810-01A...
  • Page 25: Specifications

    SPECIFICATIONS SERVICE HINTS Model Sheridan18NM When Gas Pressure Is Too Low • Input Rating: 24,000/36,000 Btu/Hr • pilot will not stay lit • Fuel: Natural Gas • burners will have delayed ignition • Ignition: Electronic • heater will not produce specified heat •...
  • Page 26: Parts

    PARTS MODELS SHERIDAN18NM, SHERIDAN18PM, SHERIDAN24NM AND SHERIDAN24PM Installed in BTB Models Only www.Astria.US.com 126810-01A...
  • Page 27 Lava Rock • • • • 111288-02 Gas Flex Line 18" • • • • 112363-01 Log Scrap Kit #1 • • • • 112364-01 Log Scrap Kit #2 • • • • ** Not a field replaceable part. www.Astria.US.com 126810-01A...
  • Page 28: Accessories

    For all models. Helps deflect heat away from mantel or wall above fireplace. Fits openings 28" to 48" wide. WALL-MOUNT ON/OFF SWITCH GWMS2 For all models. Allows the gas log heater to be turned on and off with a wall switch. www.Astria.US.com 126810-01A...
  • Page 29 NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ www.Astria.US.com 126810-01A...
  • Page 30: Warranty

    THE WARRANTY Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Astria™ brand Gas Log Set or Outdoor Gas Fire Pit ("Product") to be free from defects in materials and workmanship at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original instal- lation, IHP will, at its option, repair or replace the covered components.
  • Page 31 KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.Astria.US.com 126810-01A...
  • Page 32 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126810-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P-126810-01...