Watts QTSTMMAX-2S-10M Installation, Operation And Maintenance Manual

Watts QTSTMMAX-2S-10M Installation, Operation And Maintenance Manual

Qt steam max series

Advertisement

Quick Links

Installation, Operation and Maintenance Manual
QT
Steam Max
TM
QTSTMMAX-2S-10M, QTSTMMAX-3S-10M,
QTSTMMAX-2S-1M, QTSTMMAX-3S-1M,
QTSTMMAX-2L-10M, QTSTMMAX-3L-10M,
QTSTMMAX-4L-10M, QTSTMMAX-2L-1M,
QTSTMMAX-3L-1M, QTSTMMAX-4L-1M,
QTSTMMAX-2L-1M-P, QTSTMMAX-3L-1M-P,
QTSTMMAX-4L-1M-P
Tested and certified by WQA against NSF/ANSI
Standard 42 for the reduction of claims specified on
the performance data sheet & NSF/ANSI 372 for "lead
free" compliance .
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
WARNING
!
You are required to consult the local building and plumbing
codes prior to installation. If the information in this manual
is not consistent with local building or plumbing codes,
the local codes should be followed. Inquire with governing
authorities for additional local requirements.
Models:
TM
QTSTMMAX-4L-1M

Table of Contents

System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Replacement Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Notice to Installers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Filter Cartridge Replacement Procedure . . . . . . . . . . . . . . . . . . . 4
Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
System Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
WARNING
!
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system .
IOM-HS-QTSteamMax

Advertisement

Table of Contents
loading

Summary of Contents for Watts QTSTMMAX-2S-10M

  • Page 1: Table Of Contents

    IOM-HS-QTSteamMax Installation, Operation and Maintenance Manual Steam Max Models: QTSTMMAX-2S-10M, QTSTMMAX-3S-10M, QTSTMMAX-2S-1M, QTSTMMAX-3S-1M, QTSTMMAX-2L-10M, QTSTMMAX-3L-10M, QTSTMMAX-4L-10M, QTSTMMAX-2L-1M, QTSTMMAX-3L-1M, QTSTMMAX-4L-1M, QTSTMMAX-2L-1M-P, QTSTMMAX-3L-1M-P, QTSTMMAX-4L-1M-P Tested and certified by WQA against NSF/ANSI Standard 42 for the reduction of claims specified on the performance data sheet & NSF/ANSI 372 for "lead free"...
  • Page 2: System Specifications

    QTSTMMAX-4L-1M - 90psi (6 .2 bar) System Model Filter Ordering Code Frequency Description All Other Systems - 100psi (6 .8 bar) QTSTMMAX-2S-10M HSR-L-SED-5M 6 Months 20" 5 Micron Sediment Pre Filter Minimum Pressure: 15" QT 1 Micron Carbon Block with All Systems - 20psi (1 .4 bar)
  • Page 3: Notice To Installers

    Operation Notice to Installers • Connect the system to cold water supply only. Water Temperature With sufficient pressure, operation of this system is completely auto- cannot exceed 100°F (38°C) . matic . Dependable operation involves only monitoring system pres- • System must be installed in a vertical, upright and level position. sure differential, periodic filter changes, and service documentation .
  • Page 4: Maintenance

    Replacement Parts 9 . If no leaks are present, open the ⁄ " (8mm) drain line again and allow it to run to drain for 5 minutes to flush the system . Then close the valve . Description Ordering Code 10 .
  • Page 5 QTSTMMAX-2L-1M QTSTMMAX-2L-1M-P 5.56 15.73 15.73 5.56 4.47 4.47 26.08 26.08 14.69 25.21 QTSTMMAX-2S-1M QTSTMMAX-2S-10M 15.73 5.56 5.56 15.73 4.47 25.70 25.70 25.21 QTSTMMAX-3L-10M QTSTMMAX-3L-1M 8.01 20.30 5.56 20.30 5.56 7.22 26.08 26.08 28.35...
  • Page 6 QTSTMMAX-3L-1M-P QTSTMMAX-3S-1M 8.01 20.30 5.56 20.30 5.56 7.22 25.70 4.47 26.08 28.35 14.69 QTSTMMAX-4L-1M-P QTSTMMAX-3S-10M 5.56 20.30 5.56 24.73 4.47 26.08 25.70 14.69 QTSTMMAX-4L-10M QTSTMMAX-4L-1M 8.01 24.73 5.56 5.56 24.73 7.22 26.08 28.35 26.08 NOTICE Allow 3" (76mm) of clearance at bottom of system for removal of filter bowls for filter cartridge replacement...
  • Page 7 Notes...
  • Page 8: Limited Warranty

    For more information: www.watts.com/prop65 LIMITED WARRANTY: Watts Regulator Co. (the “Company”) warrants each QT Steam Max water filtration line system, excluding filters and water treatment cartridges, to be free from defects in material and workmanship under normal usage for a period of five years from the date of original shipment. The Company warrants all filters and water treatment cartridges to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment.

This manual is also suitable for:

Qtstmmax-2s-1mQtstmmax-3s-10mQtstmmax-2l-10mQtstmmax-3s-1mQtstmmax-3l-10mQtstmmax-4l-10m ... Show all

Table of Contents