6. Secure the connection cable onto the control board with the holder.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
12.2.4.3
Wire Stripping, Connecting Requirement
Wire stripping
No loose strand
when inserted
WARNING
RISK OF FIRE
JOINING OF WIRES MAY
CAUSEOVERHEATING
AND FIRE.
Terminal
Board
length (mm)
a b c d
Recommended
length (mm)
50 40 35 60
Indoor/outdoor
connection
terminal board
5 mm
or more
(gap between wires)
In case of indoor power supply
OR
OR
a
b
c
4
Indoor & outdoor
connection cable
Outdoor unit
Conductor
fully inserted
ACCEPT
Use complete
wire without joining.
Use approved
socket and plug
with earth pin.
Wire connection
in this area must
follow to national
wiring rules.
OR
Do not joint wires
35
Control
Board
Earth wire
d
longer than
others
AC wires
for safety
reason
Holder
Tape
Connection
cable
Conductor
over inserted
PROHIBITED
In case of outdoor power supply
OR
OR
Conductor not
fully inserted
PROHIBITED
OR