7. Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5
2
mm
flexible cord, type designation 60245 IEC 57 or heavier cord. Do not use joint connection cable. Replace the
wire if the existing wire (from concealed wiring, or otherwise) is too short. Allowable connection cable length of
each indoor unit shall be 30 mm or less.
8. Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right
escapement.
9. Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
unit according to the diagram below.
Recommended
length (mm)
10. Secure the power supply cord and connection cable onto the control board with the holder.
11. Close grille door by tighten with screw and close the front panel.
12.2.4.2
In case of outdoor power supply
3. Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5
2
mm
flexible cord, type designation 60245 IEC 57 or heavier cord. Do not use joint connection cable. Replace the
wire if the existing wire (from concealed wiring, or otherwise) is too short. Allowable connection cable length of
each indoor unit shall be 30 mm or less.
4. Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right
escapement.
5. Remove the tapes and connect the connection cable between indoor unit and outdoor unit according to the
diagram below.
Terminals on the outdoor unit
Colour of wires (connection cable)
Terminals on the indoor unit
(Power supply cord)
Terminals on the isolating devices
(Disconnecting means)
Recommended
length (mm)
a
b c d e f g
55 35 35 50 40 35 60
Tape
Power supply cord
Terminals on the isolating devices
(Disconnecting means)
(Power supply cord)
Terminals on the outdoor unit
Colour of wires (connection cable)
Terminals on the indoor unit
L
N
1
2
L
N
1
2
(L) (N)
b
e
d
a
c
Holder
6
Power supply
Indoor & outdoor
cord
connection cable
Isolating
Outdoor unit
Devices
(L) (N)
L
N
1
L
N
1
34
3
3
Terminal
Board
Control
Board
Earth wire
g
longer than
others
AC wires
f
for safety
reason
Holder
8
Tape
Connection
cable
2
3
2
3