Specifications & Dimensional Drawings; Others - Marantz CR601 User Manual

Marantz user guide cd receiver cr601
Table of Contents

Advertisement

SPECIFICATIONS & DIMENSIONAL DRAWINGS
AMP
Power Output ........30 W + 30 W (6 Ω THD=10%)
THD (Total Harmonic Distortion)
............................0.22% (15 W output 6 Ω)
Input Sensitivity and Impedance...............200 mV
Frequency Response
.......................20 Hz-90 kHz/( –3 dB /Line)
Tone Control....... +8 dB, –8 dB, 100 Hz – 10 kHz
Speaker Impedance ................................... 6–8 Ω
FM
Tuning Frequency Range
........................87.5–108 MHz 50 kHz step
Usable Sensitivity .......................2.2 µV (75ΩIHF)
S/N Ratio.............................Stereo 68 dB (IHF-A)
....................................Mono 69 dB (IHF-A)
THD (Total Harmonic Distortion)
...................................Stereo 0.3% (1 kHz)
.....................................Mono 0.2% (1 kHz)
Frequency Response
.................30 Hz–15 kHz/+1.5 dB, –1.5 dB
Stereo Separation .......................... 40 dB (1 kHz)
AM
Tuning Frequency Range
........................... 522–1611 kHz 9kHz step
Usable Sensitivity ..................................... 320 µV
S/N Ratio .................................................... 45 dB
THD (Total Harmonic Distortion) ................1.00%
DAB
Tuning Frequency Range
................174.928–239.200 MHz (BAND3)
............1452.96–1490.624 MHz (L–BAND)
Frequency Response ........ 42 Hz-16 kHz ±0.5dB
THD (Total Harmonic Distortion) ................0.06%
CD
Frequency Response ........20 Hz–20 kHz (±1 dB)
Audio Dynamic Range.................................93 dB
THD (Total Harmonic Distortion) ................0.01%
Wow and Flutter
................Below threshold of measurability
Audio Output/Impedance (Analog)
........................................1.3 V (rms) /1 kΩ
S/N Ratio .....................................................93 dB
General
Power Supply ..............................AC 230V, 50 Hz
Power Consumption .....................................74 W
Stand-by Power Consumption.....................0.8 W
Dimensions (W x H x D)
........................210 W x 146 H x 336 D mm
Weight .........................................................5.7 kg
* Specifications subject to change without prior
notice.
336
12
312
210
CD RECEIVER CR601
CD RECEIVER CR601
INPUT
INPUT
MENU
MENU
DIRECT
DIRECT
BASS
BASS
TREBLE
TREBLE
PUSH TO ENTER
PUSH TO ENTER
VOLUME
VOLUME
STANDBY
STANDBY
POWER ON / STANDBY
POWER ON / STANDBY
PHONES
PHONES
(mm)
Band III (174 to 240 MHz)
Frequency
Level
Frequency
174.928 MHz
5A
208.064 MHz
176.640 MHz
5B
209.936 MHz
178.352 MHz
5C
211.648 MHz
180.064 MHz
5D
213.360 MHz
181.936 MHz
6A
215.072 MHz
183.648 MHz
6B
216.928 MHz
185.360 MHz
6C
218.640 MHz
187.072 MHz
6D
220.352 MHz
188.928 MHz
7A
222.064 MHz
190.640 MHz
7B
223.936 MHz
192.352 MHz
7C
225.648 MHz
194.064 MHz
7D
227.360 MHz
195.936 MHz
8A
229.072 MHz
197.648 MHz
8B
230.784 MHz
199.360 MHz
8C
232.496 MHz
201.072 MHz
8D
234.208 MHz
202.928 MHz
9A
235.776 MHz
204.640 MHz
9B
237.488 MHz
206.352 MHz
9C
239.200 MHz

OTHERS

The section describes the care and maintenance tasks that must be performed to optimize the operation of
your Marantz equipment.
12
7 Cleaning of equipment external surfaces
The exterior finish of your unit will last indefinitely with proper care and cleaning, Never use scouring pads,
steel wool, scourging powders or harsh chemical agents (e.g., lye solution), alcohol, thinner, benzine,
insecticide or other volatile substances as these wil mar the finish of the equipment. Likewise, never use
cloths containing chemical substances. If the equipment get dirty, wipe the external surfaces with a soft,
lint-free cloth.
If the equipment becomes heavily soiled:
• dilute some washing up liquid in water, in a ratio of one part detergent to six
parts water.
• dip a soft, lint-free cloth in the solution and wring the cloth till it is damp.
• wipe the equipment with the damp cloth.
• dry the equipment by wiping it with a dry cloth.
7 Repairs
Only the most competent and qualified service technicians should be allowed to service the factory-
trained warranty station personnel have the knowledge and special facilities needed for repair and
calibration of this precision equipment. After the warranty period has expired, repairs will be performed for
a charge if the equipment can be returned to normal operation.
In the event of difficulty, refer to your dealer or write directly to the nearest location to you that is listed on
the Marantz Authorized Service Station list. If writing, please include the model and serial number of the
equipment together with a full description of what you think is abnormal about the equipment's behaviour.
L-Band (1452 to 1490 MHz)
Level
Frequency
Level
Frequency
9D
1452.960 MHz
LA
1473.504 MHz
10A
1454.672 MHz
LB
1475.216 MHz
10B
1456.384 MHz
LC
1476.928 MHz
10C
1458.096 MHz
LD
1478.640 MHz
10D
1459.808 MHz
LE
1480.352 MHz
11A
1461.520 MHz
LF
1482.064 MHz
11B
1463.232 MHz
LG
1483.776 MHz
11C
1464.944 MHz
LH
1485.488 MHz
11D
1466.656 MHz
LI
1487.200 MHz
12A
1468.368 MHz
LJ
1488.912 MHz
12B
1470.080 MHz
LK
1490.624 MHz
12C
1471.792 MHz
LL
12D
13A
13B
13C
13D
13E
13F
Level
LM
LN
LO
LP
LQ
LR
LS
LT
LU
LV
LW
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr401

Table of Contents