Night Setback Mode; High Power Mode; Special Remarks; Setting The Timer - Panasonic CS-MKS9NB4U Technical & Service Manual

Hide thumbs Also See for CS-MKS9NB4U:
Table of Contents

Advertisement

4. Night Setback Mode

Night Setback Mode is used for saving energy.
Press the NIGHT SETBACK button while unit is operating.
The
mark appears in the display.
To release the night setback function, press the NIGHT SETBACK
button again.
In Cooling and DRY Mode: (
When the night setback mode is selected, the air conditioner
automatically raises the temperature setting 2 °F when 30 minutes
have passed after the selection was made, and then another 2 °F
after another 30 minutes have passed, regardless of the indoor
temperature when night setback was selected. This enables you
to save energy without sacrificing comfort. This function is
convenient when gentle cooling is needed.
Setting
temperature
2 °F
30 min.
Press the NIGHT
SETBACK button

5. HIGH POWER Mode

10
and
)
2 °F
30 min.
Time
HIGH POWER mode can be used to increase the output of the
indoor unit for all operation modes.
Press the HIGH POWER button while unit is operating.
The
mark appears in the display.
To cancel, press HIGH POWER button again.
• When the HIGH POWER button is pressed, the unit operates at
maximum output for 30 minutes, regardless of the desired
temperature. The fan speed is 1 step above "High".
NOTE
Depending on the operating conditions, the fan speed may be
increased by a small amount only.

SPECIAL REMARKS

''DRY'' ( ) Operation
How it works?
• Once the room temperature reaches the level that was set, the
unit's operation frequency is changed automatically.
• During DRY operation, the fan speed automatically runs at lower
speed for providing a comfortable breeze.
• ''DRY'' operation is not possible if the indoor temperature is 59 °F
or less.
Cooling ( ) operation
• Sometimes the indoor unit may not get to the set fan speed such as
LOW under cool operation at very low outdoor temperatures due to
the indoor unit being protected from ice or frost when combined with
the outdoor unit for Low Ambient Cooling models.
Power failure during operation
• In the event of power failure, the unit will stop. When the power is
resumed, the unit will restart automatically in approximately
5 minutes by the remote controller.
Clicking Sound
Clicking sound is heard from the air conditioner
• In cooling operation, any plastic parts may shrink due to a sudden
temperature change. In this event, a clicking sound may occur. This
is normal, and the sound will soon disappear.
Remote Controller
• The remote controller sends the setting condition to the air
conditioner regularly at five minute intervals.

SETTING THE TIMER

NOTE
In the descriptions below, the following settings are used for the
temperature and time indicator selector button on the bottom front
section of the remote controller.
• Temperature: °F
• Time: AM, PM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cz-18bt1uCs-mks12nb4uCs-ks18nb4uw

Table of Contents