Download Print this page
Panasonic CS-MKE12NB4U Submittal Data
Panasonic CS-MKE12NB4U Submittal Data

Panasonic CS-MKE12NB4U Submittal Data

Multi system indoor units - ceiling recessed

Advertisement

Quick Links

Split System Submittal Data
Indoor: CS-MKE12NB4U
Multi System Indoor Units - Ceiling Recessed
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz)
Circuit Ampacity (A)
Fuse Size, Max.(A)
Running Amps (A)
Power Input (W)
Indoor Unit
Fan type
Dia & Length (in.) - No. Speeds
No. Speeds
No. Poles (RPM, High)
No. Motors (W)
CFM (HI)
Operation Sound (HI/Med/Lo)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in)
Drain Connection Size
Refrigerant
Line Size (in. O.D. Discharge)
Line Size (in. O.D. Suction)
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
Indoor Unit (Uncrated) (in.)
Weight (lbs.)
Net
Shipping
Shipping Volume (cu.ft.)
208 - 230/1/60
N/A
15
COOL .12 / .11
HEAT .14 / .13
COOL 16 / 17
HEAT 18 / 19
Cool/Heat
Turbo
D12-5/8 L5-3/4 x 1
3 & Auto
8 - 470/520
1-(23)
235/268
34/33/31-35/34/32
Aluminum Plate Fin & Copper
Tube
Slit Plate - Inner Rifled
2 - 18.1
2.94
N/A
3/4
R410A
1/4" (Flare)
3/8" (Flare)
11-13/32 x 24-13/16 x 28-1/8
12-5/16 x 24-19/32 x 24-19/32
35.3
41.9
4.59
Approval:
Date:
Construction:
Unit#:
Drawing#:
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity (BTU/H)
Moisture Removal (HI, Pint/H)
Heating
Total Capacity (BTU/H)
Features
Controls
Remote Control
Temperature Control
Timer
Night Setback
Air Louver
Power Failure Automatic Restart
Self-Diagnosis
Quiet Operation
Air Filter
Option
Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Condensate Drain Pump
Hard Wired Remote Controller
Non-Removeable Remo-con
Bracket
Operating Range
Indoor Air Intake Temp
Cooling (Max)
95F DB/71F WB
Cooling (Min)
67F DB/57F WB
11900
4.26
13600
Microprocessor
LCD Wireless Type, Built-in Temp
Sensor
IC Thermostat
24 Hr. Program, 1 Hr. Off
Built-In
Automatic
Built-In
Built-In
Built-In
Washable, Anti-Mold
Available
Knock-out
N/A
Standard
Available
Available
Outdoor Air Intake Temp
115F DB
14F DB

Advertisement

loading

Summary of Contents for Panasonic CS-MKE12NB4U

  • Page 1 Split System Submittal Data Indoor: CS-MKE12NB4U Multi System Indoor Units - Ceiling Recessed Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit#: Submitted by: Drawing#: Reference: General Data Power (V/P/Hz) 208 - 230/1/60 Circuit Ampacity (A) Fuse Size, Max.(A) Running Amps (A) COOL .12 / .11...
  • Page 2: Indoor Dimensions

    If the suspension bolts is too long, it will contact 1-27/32 1-3/32 the ceiling panel and the unit cannot be installed. Unit : inch (mm) Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon...