Specifications

Typical System Flow Sequence . Particle Filter, Activated Carbon Filter, Reverse Osmosis Membrane, Specialty Filter,
Particle Filter. . . . . . . . . . . . . . . . . 1, 2 or 3
Activated Carbon Filter . . . . . . . . Activated Carbon or Activated Carbon Block
Reverse Osmosis Membrane . . . Culligan
. . . . . . . . . . . . . Aqua-Cleer 30 Models
Production Rate
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Aqua-Cleer 50 Models
Ratio of Product to Flush Flow
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Applications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Soft Water Applications
Polishing Filter . . . . . . . .. . . . . . . Activated Carbon or Carbon Block
Specialty Cartridges
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Arsenic Cartridge
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Total Defense (MTBE, VOC Reduction)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Perchlorate Cartridge*
Dispensing Faucet . . . . . . . . . . . . Culligan Aqua-Cleer Faucet: Rotary Operation, Stainless Steel and Resin Flow Passages,
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Colors
Storage Capacity
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Tank
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Medium Tank
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Large Tank
Dimensions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Assembly
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Storage Tank
1
Rating at 50 psi, 77°F, 500 mg/L TDS influent, without storage tank.
2
May vary with pressure. See "Replace Flow Control", page 10, for all hard water applications and applications where TDS
exceeds 1000 mg/L (ppm).
3
Arsenic and Perchlorate cartridge must be installed after the RO membrane and system must have a Performance
Indicator Device (PID) installed to track gallon usage.
Influent Water Characteristic
Pressure
Temperature
Total Dissolved Solids (TDS)
pH
Chlorine
2
Chloramine
Turbidity
Hardness
3
Iron
Bacterial Quality
* Cartridge not for sale in California.
2
Culligan
Aqua-Cleer
Drinking Water Systems
®
®
Storage Tank, Polishing Filter, Dispensing Faucet
Aqua-Cleer
®
2
with Built-in Siphon Break
Brushed Nickel, Polished Chrome or White
2 gallons (7.5 L)
3 gallons (10.5 L)
9 gallons (34 L)
13.8" W x 4.2" D x 15.5" H (35 cm W x 10.7 cm D x 39.4 cm H)
• Std. 9" Diameter x 15"H (23 cm Diameter x 38 cm H)
• Med. 11" Diameter x 15"H (28 cm Diameter x 38 cm H)
• Lrg. 15.5" Diameter x 22"H (40 cm Diameter x 56 cm H)
40 - 120 psi
33 - 100 ºF
0 - 2500 ppm (0 - 2500 mg/L)
1
5 - 10
0 - 3 ppm (0 - 3 mg/L)
0 - 3 ppm (0 - 3 mg/L)
0 - 10 NTU
0 - 10 gpg
0 - 1 ppm (0 - 1 mg/L)
Potable
Thin Film Composite
®
36 gpd (119 L/day)
50 gpd (189 L/day)
1:3 - 1:5 (Aqua-Cleer-30 models only)
1:1
1000 gallons
1000 gallons
1000 gallons
Notes
1.
See the "Performance & Technical Information" section for all
applications where TDS exceeds 1000 ppm. A booster is strongly
recommended to improve the reduction of TDS. Higher pressures
will help maintain the membrane's maximum rejection performance.
2.
The reverse osmosis membrane used in these systems may be
damaged by chlorine. These systems include activated carbon
filters which protect the membranes by reducing chlorine. Influent
chlorine should not exceed 3 mg/L.
3.
A softener is strongly recommended for water over 10 gpg hard.
Installing a system without a softener on water with hardness higher
than 10 gpg will reduce the life of the membrane.
4.
Additional information on factors that affect RO performance can be
found in the "Performance & Technical Information" section.