Specifications

Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
26
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
NG
LP
45°F Rise
pressure, water supply, piping conditions, and water temperature.
N-0931M-DV-ASME
Indoor, Wall Mounted
Direct Vent (Sealed Combustion)
24.4"(Height) x 18.4"(Width) x 9.4"(Depth)
120 VAC (60Hz)
NG : 115W LP : 120W
Stainless Steel
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR), Overheat Prevention
Device, Freezing Prevention Device, Fan Rotation Detector
Remote Controller, Remote Controller Cord,
Anchoring Screws
Maximum Performance
250,000 btuh
250,000 btuh
0.5-11.1 Gal./min.
100-150°F (In 5°F intervals),
160, 170, 180°F (In 10°F intervals) (14 Options)
120,130,140,180°F (Original is 120°F)
Specification
Direct Ignition
15-150 psi
0.5 GPM
62 lbs.
0.3 Gallon
3/4"
3/4"
3/4"
Freeze Prevention 250W
Minimum Performance
11,000 btuh
11,000 btuh
9.3 Gal./min.