Performance
Data Sheet
SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANS142/53 for reduction of the substances listed below.
The concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142/53.*
100% safety factors built in for unmetered usage)
Parameter
USEPA
Influent
MCL
Challenge
Concentration
Chlorine
-
2.0mg/L+ 10%
T&O
-
-
Particulate**
-
I
->10,000 partictes/mL
Standard No. 42: Aesthetic Effects
Influent
_fn,,on_
Average
Average
Maximum
1.96 m g/L
0.06mg/L
0.ii m g/L
6,400,000
#/mL
58,833 #/mL I 150,000 #/mL
i
o/. I_orh it-finn
Average
Minimum
96.77%
94.74%
199.14%
97.97%
Min. Required
Reduction
> 50%
->85%
Parameter
Turbidity
Cysts
Asbestos
Lead at pH 6.5
Lead at pH 8.5
Mercury at pH 6.5
Mercury at pH 8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dichlorobenzene
Atrazine
USEPA
MCL
0.5NTU
> 99.95% Reduction
> 99%Reduction
0.015 m g/L
0.015 m g/L
0.002 m g/L
0.002 m g/L
0.002 m g/L
0.0002 mg/L
0.070 m g/L
0.003 m g/L
0.005 m g/L
0.040 m g/L
0.075 m g/L
0.003 m g/L
Standard No. 53: Health Effects
Influent
Challenge Concentration
11+ 1 NTU***
Hinimum 50,000L
107to 10_fibers/L; > 1%m
0.15 my/L_+ 10%
0.15 my/L_+ 10%
0.006 my/L+ 10%
0.006 my/L+ 10%
0.04 my/L+ 10%
0.002 my/L+ 10%
0.210 mg/L_+10%
0.015 my/L+ 10%
0.015 my/L+ 10%
0.080 mg/L+ 10%
0.225 my/L_+ 10%
0.009 my/L+ 10%
Influent
Average
10.5NTU
118,750 #/L
57HF/L
0.1567mg/L
0.1455mg/L
0.0059mg/L
0.0057mg/L
0.0567mg/L
0.0020mg/L
0.2055mg/L
0.0160mg/L
0.0145mg/L
0.0850mg/L
0.2285mg/L
0.0087mg/L
Average
0.14NTU
< 1#/L
0.996MF/L
< 0.001mg/L
< 0.001mg/L
0.000550 mg/L
0.000525 mg/L
0.00025 mg/L
<0.00002 mg/L
0.00557 mg/L
0.00100 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
Maximum
0.28NTU
4#/L
< 1MF/L
< 0.001mg/L
< 0.001mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
<0.00002 mg/L
0.011000 mg/L
0.001000 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
oI_ Rod1 irflnn
Average
Minimum
98.54%
97.20%
> 99.99%
> 99.99%
99.60%
99.59%
99.56%
99.29%
99.50%
99.29%
94.70%
87.50%
95.20%
89.29%
99.54%
98.67%
99.00%
98.95%
98.52%
94.50%
95.44%
91.67%
96.51%
95.85%
98.78%
98.65%
99.78%
99.77%
94.22%
95.55%
Min. Required
Reduction
0.5NTU
> 99.95%
> 99%
0.010mg/L
0.010 m g/L
0.002 m g/L
0.002 m g/L
0.002 m g/L
0.0002 mg/L
0.070 m g/L
0.005 m g/L
0.005 m g/L
0.04 m g/L
0.075 m g/L
0.005 m g/L
+
.
o+
o
o+
o
* Tested using a flow rate o1:0.50gpm; pressure o1:60psig; pH of 7.5 _ 0.5, temp. o1:68 _ 5 F (20 _ 5 C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating
Specifications
• Capacity: certified for up to 300 gallons (1135 I); up to six months for models without a replacement
filter indicator light;
up to one year for models with a replacement
filter indicator light
• Pressure requirement:
40-120
psi (2.8-8.2 bar), non-shock
• Temperature:
33-100°F
(0.6-38°C)
• Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance
Requirements
• Flush new cartridge
at full flow for 3 minutes to purge out trapped
air.
• Replace cartridge
when the indicator
light flashes or water flow rate is reduced on non-indicator
units.
Special
Notices
• Installation
instructions,
parts and service availability,
and standard
warranty
are included with the product when shipped.
• This drinking water system must be maintained according to manufacturer's
instructions, including replacement
of filter cartridges.
• Do not use with water that is microbiologicallg
unsafe or of unknown
quality
without
adequate
disinfection
before or
after the system.
Systems certified
for cyst reduction
may be used on disinfected
water that may contain filterable
cysts.
• The contaminants
or other substances
removed or reduced by this water treatment
system are not necessarily
in your water.
• Check for compliance
with the state and local laws and regulations.
• Note that while the testing was performed
under standard
laboratory
conditions,
actual performance
may vary. Systems must be
installed and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY40225
EPA EST.No. 070595-1VlN-OO1
25