Maytag MEDC215EW0 Installation Instructions Manual page 11

29" wide models
Hide thumbs Also See for MEDC215EW0:
Table of Contents

Advertisement

ground wire and neutral
wire
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
6, Connect neutral ground wire
and neutral
wire
Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with hold-
down screw. Now, go to Venting Requirements.
3=wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
3.
Prepare your 3-wire cable for
direct
connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 31/2'' (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
4, Connect
wires to terminal
block
To connect wires to terminal block, place hooked end of wire
under terminal block screw, facing to the right, squeeze hooked
end together and tighten screw.
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
Remove center terminal block screw (B).
11