Overview Of Units; Unit Construction - Mitsubishi Electric PUMY-P112VKM1 Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P112VKM1:
Table of Contents

Advertisement

2

OVERVIEW OF UNITS

2-1. UNIT CONSTRUCTION

Outdoor unit
Capacity
Applicable
indoor unit Number of units
Total system wide capacity
Branching pipe
components
Model
Cassette Ceiling
4-way flow
2-way flow
PLFY-P
PLFY-P
Capacity
-
-
-
15
20VCM-E(2)
20VLMD-E
20
25VCM-E(2)
25VLMD-E
25
32VCM-E(2)
32VLMD-E
32
32VBM-E
40VCM-E(2)
40VLMD-E
40
40VBM-E
50VBM-E
50VLMD-E
50
63VBM-E
63VLMD-E
63
71
80VBM-E
80VLMD-E
80
100VBM-E 100VLMD-E
100
125VBM-E 125VLMD-E
125
140
Decorative panel
Name
Model number
Remote
controller
• A handy remote controller for use in
Functions
• Addresses must be set.
*1. PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*2. When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110% (100%
in case of heating below −5: [23˚F]).
*3. When connecting PWFY series
• Only 1 PWFY-P100VM-E-AU can be connected. PWFY-P200VM-E-AU and PWFY-P100VM-E-BU cannot be connected.
• T he PWFY unit cannot be the only unit connected to an outdoor unit. Select an indoor unit so that the total rated capacity of the indoor
units, excluding the PWFY unit, is 50 to 100% of the outdoor unit capacity.
*4. When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
OCH576
4HP
PUMY-P112VKM1(-BS)
PUMY-P112YKM1(-BS)
Type 15 to Type 125
1 to 9 unit
CMY-Y62-G-E
Branch header
(2 branches)
Ceiling
Wall
1-way flow
Concealed
Mounted
PMFY-P
PEFY-P
PKFY-P
15VMS1(L)-E
15VBM-E
20VMS1(L)-E
20VBM-E
20VBM-E
/ VMA(L)-E
25VMS1(L)-E
25VBM-E
25VBM-E
/ VMA(L)-E
32VMS1(L)-E
32VBM-E
32VHM-E
/ VMA(L)-E
40VMS1(L)-E
40VBM-E
40VHM-E
/ VMA(L)-E/ VMH-E
50VMS1(L)-E
50VHM-E
/ VMA(L)-E/ VMH-E
63VMS1(L)-E
63VKM-E
/ VMA(L)-E/ VMH-E
71VMA(L)-E
/ VMH
80VMH-E
/ VMA(L)-E
100VMH-E
100VKM-E 100VKM-E
/ VMA(L)-E
125VMH-E
/ VMA(L)-E
140VMH-E
/ VMA(L)-E
M-NET remote controller
PAR-F27MEA-E
conjunction with the Melans centralized
management system.
5HP
PUMY-P125VKM1(-BS)
PUMY-P125YKM1(-BS)
1 to 10 unit
50 to 130% of outdoor unit capacity *2 *3
CMY-Y64-G-E
Branch header
(4 branches)
Ceiling
Floor standing
Suspended
Exposed
Concealed
PFFY-P
PFFY-P
PCFY-P
20VLEM-E
20VLRM-E
VKM-E(2)
25VLEM-E
25VLRM-E
VKM-E(2)
32VLEM-E
32VLRM-E
VKM-E(2)
40VLEM-E
40VKM-E
40VLRM-E
VKM-E(2)
50VLEM-E 50VLRM-E
63VKM-E 63VLEM-E 63VLRM-E
125VKM-E
MA remote controller
PAR-21MAA, PAR-30/31MAA
PAR-W21MAA(when using PWFY)
• Addresses setting is not
necessary.
5
6HP
PUMY-P140VKM1(-BS)
PUMY-P140YKM1(-BS)
Type 15 to Type 140
1 to 12 unit
CMY-Y68-G-E
Branch header
(8 branches)
Ceiling
Air to Water
Concealed
Unit *3
(Fresh Air) *1
PEFY-P
PWFY-P
80VMH-E-F
100VM-E-AU
140VMH-E-F
M series remote controller
CONNECTION KIT
PAC-LV11M-J
M series indoor unit *4
MSZ-GF Series
MSZ-SF Series
MSZ-EF Series
MSZ-FH Series
MFZ-KJ Series