Removing The Compressor (Mc); Removing The Accumulator - Mitsubishi Electric PUMY-P112VKM1 Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P112VKM1:
Table of Contents

Advertisement

OPERATING PROCEDURE

13. Removing the compressor (MC)

(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove 2 front cover panel fixing screws (5 × 12) and
remove the front cover panel. (See Photo 4)
(4) Remove front panel fixing screws, 5 (5x12) and 2 (4 x 10)
and remove the front panel. (See Photo 4)
(5) Remove 4 back cover panel fixing screws (5 × 12) and
remove the back cover panel.
(6) Remove the electrical parts box. (See Photo 5)
(7) Remove 3 valve bed fixing screws (4 × 10) and 4 ball valve
and stop valve fixing screws (5 × 16) and then remove the
valve bed. (See Photo 4 and 7)
(8) Remove 3 right side panel fixing screw (5 × 12) in the rear
of the unit and then remove the right side panel.
(9) Remove 3 separator fixing screws (4 × 10) and remove the
separator. (See Figure 1)
(10) Recover refrigerant.
(11) Remove the 3 compressor fixing nuts for motor using span-
ner or adjustable wrench.
(12) Remove the welded pipe of motor for compressor inlet and
outlet and then remove the compressor.
Note: Recover refrigerant without spreading it in the air.

14. Removing the accumulator

(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove 2 front cover panel fixing screws (5 × 12) and remove the front cover panel. (See Photo 4)
(4) Remove 4 back cover panel fixing screws (5 × 12) and remove the back cover panel.
(5) Remove the electrical parts box. (See Photo 5)
(6) Remove 3 valve bed fixing screws (4 × 10) and 4 ball valve and stop valve fixing screws (5 ×16), and then remove the
valve bed. (See Photo 4 and 7)
(7) Remove 3 right side panel fixing screw (5 × 12) in the rear of the unit and then remove the right side panel.
(8) Recover refrigerant.
(9) Remove 2 welded pipes of accumulator inlet and outlet.
(10) Remove 2 accumulator leg fixing screws (4 × 10). (See Photo 15)
Note: Recover refrigerant without spreading it in the air.
Photo 14
OCH576
Photo 13
Valve bed
Valve bed
fixing screw
Compressor
(MC)
Separator
Figure 1
Inlet
Outlet
Accumulator
Accumulator leg fixing
screws
148
PHOTOS
Separator
fixing screw
Photo 15
Valve
bed fixing
screws
Accumulator
Compressor
fixing nuts
Separator
fixing
screws
Accumulator
Accumulator leg

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents