For Service - Crosley CAHWE12ER410A12 Use & Care Manual

Table of Contents

Advertisement

Before
calling
for s ervice,
review
this l ist, Itmay save you t ime and expense,
This list includes
common
occurrences
that are n ot
the r esult of d efective
workmanship
or materials
inthis a ppliance
OCCURRENCE
SOLUTION
Air conditioner
will not operate,
Air from unit does not feel cold
enough.
Wall
plug
disconnected.
Push plug
firmly
into wall
outlet.
Plug Current
Device
Tripped.
Press the
RESET
button.
House
fuse
blown
or circuit
breaker
tripped.
Replace
fuse
with time
delay
type
or reset circuit
breaker.
Control
is OFF. Turn
Control
ON and set to desired
setting.
Room
temperature
below
60°F
(16°C).
Cooling
may
not
occur
until
room
temperature
rises
above
60°F
(16oC).
Temperature
sensing
element
touching
cold
coil, located
behind
air filter.
Straighten
away
from
coil.
Reset to a lower
temperature.
Compressor
shut-off
by changing
modes.
Wait
approximately
3 minutes
and
listen for
compressor
to
restarL
when
set in the COOL
mode.
Air conditioner
cooling,
but room
is too warm
- ice forming
on cooling coil behind
decorative
front
Air conditioner
cooEng_ but room
is too warm
- NO ice forming
on
cooling coil behind
decorative
front.
Air conditioner
turns
on and off
rapidly.
Noise when unit
is cooling.
Water
dripping
INSIDE
when
unit
is cooling.
Outdoor
temperature
below
60 °F (16 °C). To defrost
the
coil, set
FAN ONLY mode.
Air filter
may
be dirLy.
Clean
filter.
Refer
to Care
and
Cleaning
section.
To defrost,
set to FAN ONLY
mode.
Temperature
is set too
low for night-time
cooling.
To defrost
the
coil,
set to FAN
ONLY mode.
Then,
set temperature
to a higher
setUng.
Dirty
air filter
- air restricted.
Clean
air filter.
Refer
to Care
and Cleaning
section.
Temperature
is set too
high.
Set temperature
to a lower
set:Ling.
Air directional
louvers
positioned
improperly.
Position
louvers
for better
air distribution.
Front
of unit
is blocked
by drapes,
blinds,
furniture,
etc.
- restricts
air distribution.
Clear
blockage
in
front
of unit.
Doors,
windows,
registers,
etc. open
- cool air escapes.
Close
doors,
windows,
registers,
etc.
Unit
recently
turned
on in hot
room.
Allow
additional
time
to remove
"stored
heat"
from
wails, ceiling,
floor
and
furniture.
Dirty air filter - air restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a faster setLing to bring air through cooling coils
more frequently.
Air movement sound. This is normal. If too loud, set to lower FAN setUng.
Sound of fan hitting water-moisture removal system. This is normal when humidity is high. Close
doors, windows and registers.
Window vibration - poor installation. Refer to installation instructions or check with installer.
Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to
installation instructions or check with installer.
Water
dripping
OUTSIDE
when
Unit removing large quantity of moisture from humid room. This is normal during excessively humid
unit is cooling,
days.
Room too cold.
Set temperature too low. increase set temperature.
:If These
Solutions
Fail, Call :[=800=944=9044
For Service,