DESCRIPTION
TheCraftsman 18gaugeBradNailer d rivesbrads
from5/8"to2-1/8" long.Oilless design eliminates
dailyoilingandoilstains onworkpiece. Diecastmag-
nesium bodywithtextured rubber g ripminimizes o p-
eratorfatigue. L arge capacity, sideloading magazine
withpositive, quickactionlatchmakes loading easy.
Nailerfeatures rearexhaust, s inglerapid-fire oper-
ation, a djustable d epth of drivecontrol, n o-mar t ip
andstorage case. S afety feature disables toolunless
contact t ip is pressed against workpiece. Tapered
toolnoseprovides o perator w ithgreater v isibility for
precise fastner placement. Rigidtoolnosereduces
jamming. The18Guage BradNaileris excellent for
molding, furniture making andpicture framing.
AIRSUPPLY LINE
SeeFigure 3
DANGER:Donotuseoxygen, c arbon dioxide,
high-pressure compressed gasor bottled gasesas
thepower source forthistool. Thetoolwillexplode
andserious personal injury couldresult.
Theairtooloperates o ncompressed a iratpres-
suresfrom70-120 PSI
Neverconnect thetooltoairpressure w hich
couldpotentially
e xceed 200 PSI. Use only
clean, dry, regulated air within rate range as
marked on tool.
Air delivery
Required:
0.94 SCFM @ 90 PSI. (30
shots per minute).
WARNING:
Keep hands and body away from
discharge area of tool when connecting air supply.
Always disconnect tool from air supply when servic-
ing or adjusting tool and when tool is not in use.
Air operated tools require clean, dry, lubricated
compressed air to ensure top performance, low
maintenance and long life.
Dirt and abrasive materials present in all air lines
will damage tool O-rings, valves and cylinders.
Moisture will reduce tool performance and life if
not removed from compressed air.
The air supply system must be able to provide
air pressure of 70-120 pounds per square inch at
tool.
All hoses and pipes in the air supply system must
be clean and free of moisture and foreign parti-
cles. Hoses must be rated for maximum working
pressure of 150 PSI or 150% of maximum system
pressure, whichever is greater.
Do not mount swivel connector in air supply line.
The air pressure should be properly regulated.
Different workpiece materials and different
fastener lengths will require different operating
pressure.
Be sure all connections in air supply system are
sealed to prevent air loss.
WARNING: This tool is equipped with a male, free-
flow coupling for air supply connection. To prevent
accidental discharge and possible injury, NEVER
remove the male coupling to replace with a female
coupling.
To connect
tool to air supply:
1.
Firmly hold tool by its handle with one hand. Be
sure to point tool away from you and others in the
area.
2.
With other hand, insert female coupling of air
hose over male coupling of tool until hose cou-
pling is firmly seated.
CAUTION: When connecting or disconnecting air
hose, air pressure may cause the the hose coupling
to kick back if the hose coupling is not firmly seated
on tool coupling.
NOTE: When hose is disconnected from tool, snap
the dust cap over the tip of the tool male coupling.
Figure 3-Air Supply Line
LOADING
See Figures 4-6 (Pages 4 & 5)
WARNING: To avoid serious injury, disconnect tool
from air supply. Do not load tool until you are ready
to use it. Do not pull trigger or depress contact trip
while loading tool. Make sure that the tool noseplate
is securely closed before loading fasteners. Always
load with nose of tool pointing away from you and
others. Always wear safety goggles that comply with
United States ANSI Z87.1.
Depress the magazine cover release latch and
slide the magazine cover open. (See Figure 4)
Figure 4-Open Magazine Cover