Electrical Requirements - GE JK3000DF3WW Installation Instructions Manual

27" & 30" electric built-in wall ovens
Hide thumbs Also See for JK3000DF3WW:
Table of Contents

Advertisement

Available languages

Available languages

_1
DOOR REMOVAL
(RECOMMENDED)
NOTE: Door removal
is not a requirement
for installation
of the product
but is an added
convenience.
To remove
the door:
A. Open the oven door as far as it will go.
B. Remove
hinge
bracket
from front frame
and set aside. The hinge
bracket
must
be replaced
for proper
door functionality
when
door is reinstalled.
C. Push both
hinge
locks down toward
the door frame
to the unlocked
position.
This may require
a flat-blade
screwdriver.
DO NOT LIFT THE DOOR BY THE
HANDLE!
D. Place hands
on both sides of the door and (:lose the oven door to the removal
position
(approximately
1"-2"
[2.5 cm-5.1
cm] from the closed
position).
E. Lift the door up and out until the hinge arms
(:lear the slots.
NOTE: The oven door is very heavy.
Be sure
you have a firm grip before
lifting the oven door off the hinges.
Use caution
once the door is removed.
Do not lay the door on its handle.
This could
cause dents
or scratches.
/
I_
Hinge Unlocked
Hinge Slot
Hinge Arm
Position
Hinge Clears Slot
Hinge Bracket
ELECTRICAL REQUIREMENTS
WARNING:This app,iance
m, st
be p roper,y
grounded.
WARNING:
To preverlt fire or shock, do rlot use arl extensk)n
cord with this app,iarlce.
a, WARNING:
To prevent shock, remove house fuse or operr circuit
breaker
before
beginning
irrstallation.
a, WARNING:
Improper
corrrrectiorl
of alurnirlum
house wirirlg
to copper leads carl result
in an electrical
hazard or fire. Use only corrnectors
designed
forjoining
copper to aluminum
arrd follow the
manufacturer's
recommended
procedure
closely.
We recommend
you have the electrical
wiring arrd hookup
of your appliance
corrnected
by a qualified
electrician.
After irrstallation,
have the electrician
show you how to disconnect
power from the appliance.
You must use a single-phase,
120/208
VAC or 120/240
VAC, 60 Hertz electrical
system.
If you corrnect
to
aluminum
wiring, properly
installed corrnectors
approved
for use with aluminum
wiring
must be used.
Effective January
1, 1996, the National
Electrical
Code requires
that new construction
(not existing)
utilize
a four-conductor
connection
to an electric
oven. When
installing
an electric
oven in new construction,
a mobile
home,
recreational
vehicle
or an area where
local codes prohibit
grounding
through
the
neutral
conductor,
refer to the section
on four-conductor
branch
circuit
connections.
Check with
your
local utilities
for electrical
(:odes which
apply
in your
area. Failure
to wire your oven
according
to governing
codes
could result
in a hazardous
condition.
If there
are no local (:odes, your
oven must be wired
and fused to meet the National
Electrical
Code, NFPA No. 70 - latest edition,
available
from the National
Fire Protection
Association.
F_
ELECTRICAL
REQUIREMENTS
(CONT.)
This appliance
must be supplied with the proper voltage
arrd frequency
and corrnected
to an individual,
properly
grounded
branch circuit,
protected
by a circuit
breaker or fuse. See the rating plate located
on the
oven frame to determine
the rating of the product.
Rating
P|ate
Location
....................................
Rating plate
is located
on the oven side trim.
Use the chart below to determine
the minimum
recommended
dedicated
circuit
protection:
Recommended
KW Rating
KW Rating
Circuit
Size
240V
208V
(Dedicated)
<4.8 KW
<4.t
KW
20 Amp
4.9 KW-7.2
KW
4.2 KW-6.2
KW
30 Amp
7.3 KW-9.6
KW
6.3 KW-8.3
KW
40 Amp
9.7 KW-12.0
KW
8.4 KW-IO.4
KW
50 Amp
DO NOT shorten
the flexible
corrduit. The conduit
strain relief clamp must be securely attached
to the
junction
box and the flexible corrduit
must be securely
attached
to the clamp. If the flexible
conduit
will not
fit within the clamp, do not irrstall the oven until a clamp of the proper size is obtained.
The 3 power leads supplied with this appliance
are suitable
for connection
to heavier gauge
household
wiring. The irrsulation of these 3 leads is rated for temperatures
much higher than the temperature
rating of
the household
wiring. The current-carrying
capacity
of the corrductor
is governed
by the wire gauge
and the
temperature
rating of the irrsulation
around
the wire.