24. When servicing a tool, use only identical
replacement parts. Follow instructions in
the Maintenance section of this manual.
USE PROPER EXTENSION CORD: Use only three-wire extension cords that have three-
prong grounding-type plugs and three-pole receptacles that accept the tool's plug. Make
sure your extension cord is in good condition. Replace or repair damaged or worn cord
immediately. When using an extension cord, be sure to use one heavy enough to carry the
current your product will draw. An undersized cord will cause a drop in line voltage resulting
in loss of power and overheating. Table 1 shows the correct size to use depending on cord
length and nameplate ampere rating. If in doubt, use the next heavier gage. The smaller the
gage number, the heavier the cord.
Ampere Rating
More Than
0
6
10
12
GROUNDING INSTRUCTIONS
This tool should be grounded while in use to protect the operator from electric shock. The
tool is equipped with a three-conductor cord and three-prong grounding type plug to fit the
proper grounding type receptacle. The green (or green and yellow) conductor in the cord is
the grounding wire. Never connect the green (or green and yellow) wire to a live terminal.
Your unit is for use on 120 volts and has a plug that looks like Fig. "A".
An adapter Fig. "B" and "C" is available for connecting Fig. "A" type plugs to two-prong
receptacles. The green-colored rigid ear, lug, etc., extending from the adapter must be con-
nected to a permanent ground, such as a properly grounded outlet box.
Grounding
Blade
4
Table 1: Minimum gage for cord
Not More Than
6
10
12
16
Cover of Grounded
Fig. A
Use of unauthorized parts or failure to follow
Maintenance instructions may create a risk of
electric shock or injury.
Volts
Total length of cord in feet
120 V
25 ft.
18
18
16
14
Outlet Box
Fig. B
50 ft.
100 ft.
AWG
16
16
16
14
16
14
12
Not Recommended
Adapter
Grounding Means
Fig. C
150 ft.
14
12
12