LEDs
1 2 3
4
5 6 7 8
1 2 3 4
5
6 7 8
1 2 3 4
5 6
1 2 3 4
5 6 7
1 2 3 4
5 6
1 2 3 4
5
6
1 2 3 4
5
6 7
1 2 3 4
5
6
1 2 3 4
5 6 7 8
1 2 3 4 5
6
Technical Manuals Online! - http://www.tech-man.com
Message
A wireless keyfob or
remote arming device
has a low battery.
A keypad is malfunc-
tioning.
7 8
Phone line 2 is not
working.
8
Brown out (power loss
short of total failure)
7
8
Electrical power from
the system has short-
circuited to the ground
wire.
7
8
The external bell/siren
needs service.
8
Self-diagnostic failure of
a sensor.
7 8
Phone line 1 not
working.
There are too many
messages to be sent to
the monitoring station.
7 8
The monitoring station
(phone #2) does not
answer.
(Table continued on next page)
What to do
The second row of zone LEDs
light in a binary pattern to identify
which device has the low battery.
To replace the battery, call for
service.
Call for service.
If line is functioning, call
monitoring station. If not, call
telephone company for service.
When power returns to normal,
the system should revert to
normal functioning. If not, call for
service.
Call for service.
Call for service.
Call for service.
If line is functioning, call
monitoring station. If not, call
telephone company for service.
If the telephone line is functioning,
contact your monitoring station. If
not, report the problem to the
telephone company.
If the telephone line is functioning,
contact your monitoring station. If
not, report the problem to the
telephone company.