Vivax ACP-18CH50GEI Service Manual page 30

Table of Contents

Advertisement

Operating Procedures / Photos
Disassemble Capillary
Unsolder the four welding points connecting the two
capillary sub-asslies with the liquid valve and the
condenser, and remove the capillary sub-assy.
As show in Fig.7-22)
Disassemble Gas Valve and Liquid Valve
Unscrew the four bolts fixing the two valves,
unsolder the welding point connecting the gas valve
with the return-air pipe, and remove the gas valve
(caution: when unsoldering the soldering point,
wrap the gas valve completely with wet cloth, so as
to prevent the valve body from harmed by high
temperature). Unscrew the four bolts fixging the
liquid valve, and remove the liquid valve.
(refer to Figure 7-23)
Disassemble Compressor
Unscrew the six nuts with washers at the feet of the
two compressors (caution: only after discharging all
freon). Unsolder the suction and the discharge pipes
of the compressor, carefully remove the pipes and
take out the compressor.
(refer to Figure 7-24)
Capillary
Liquid Valve
Gas Valve
Compressor
Fig.
Bolt
Bolt
Fig.
Fig.