AIR CONDITIONER FEATURES(CONTINUED)
FOLLOW ME FEATURE:
Auto
Auto
Low
Cool
Med
Dry
Fan
High
Mode
Fan
Follow
Me
Energy
On/Off
Saver
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in your control that
you should become familiar with.
The Cool circuit has an automatic 3 minutes time delayed start if the unit is turned off and on
quickly. This prevents overheating of the compressor and possible circuit breaker tripping.
The fan will continue to run during this time.
The control will maintain any set temperature within 1 F, between 62 F(17 C) and 86 F(30 C) degrees.
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.
To convert from one to the other, press and hold the Left and Right Temp/Timer buttons at the
same time for 3 seconds.
Fresh Air Vent Control(
Figure 1 (VENT CLOSED)
Figure 2 (VENT OPEN)
Light flashing
10,000Btu/ 12,000Btu Models)
The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (See Fig.1)
2. Draw fresh air into the room- Vent Open (see Fig.2)
3. Exchange air from the room and draws fresh air into
NOTE:
This feature can be activated from the remote
control ONLY. The remote control serves as a
remote thermostat allowing for the precise
temperature control at its location.
To activate the Follow Me feature, point the remote
control towards the unit and press the Follow Me
button. T
he remote display is actual temperature
at its location. The remote control will send this
signal to the air conditioner every 3 minutes interval.
If the unit does not receive the Follow Me signal
during any 7 minutes interval, the unit will beep to
indicate the Follow Me mode has ended.
The actual temperature can be displayed at the unit
by pressing the Fan Only mode. When in the Cool
mode, the unit display indicates the set temperature.
:
the room - Vent and Exhaust Open (see Fig.3)
Figure 3 (VENT & EXHAUST OPEN)