Bryant 619E Installation, Start-Up And Service Instructions Manual page 19

High wall fan coil units
Table of Contents

Advertisement

TEMP
MINIMUM
(F)
OHMS
−40
303,300
−30
211,500
−20
149,721
−10
107,379
0
77,281
10
56,567
20
42,661
30
32,043
32
30,300
40
24,061
50
18,650
60
14,402
70
11,247
80
8,820
90
6,846
100
5,487
110
4,367
120
3,502
130
2,830
140
2,300
150
1,880
160
1,547
170
1,280
180
1,065
190
890
200
748
210
631
212
611
*Circuit volts = 5 vdc.
Table 9 — System Fault Codes
NO. OF QUICK
LED FLASHES
2
3
4
5
6
7
8
9
LED — Light-Emitting Diode
*Heat pump systems only.
NOTE: If the LED light continuously flashes on for one second, then
off for one second, the control is functioning properly and no fault is present.
Table 10 — 619E Thermistor Properties*
NOMINAL
MAXIMUM
OHMS
OHMS
342,700
386,200
237,276
265,444
166,689
185,146
118,776
130,973
85,677
93,867
62,617
68,205
46,302
50,129
34,580
37,220
32,550
35,120
26,118
27,960
19,900
21,180
15,312
16,219
11,883
12,518
9,299
9,779
7,339
7,754
5,829
6,187
4,667
4,976
3,760
4,026
3,051
3,281
2,489
2,687
2,045
2,216
1,688
1,836
1,402
1,531
1,170
1,282
982
1,078
828
913
701
766
678
751
—19—
SYSTEM FAULT
Room Air Thermistor
Indoor Coil Thermistor
Outdoor Coil Thermistor*
Compressor Malfunction
Reversing Valve Malfunction*
Outdoor Air Thermistor*
Indoor Fan Failure
Discharge Air Thermistor
MINIMUM
THERMISTOR
THERMISTOR
VOLTS — DC
VOLTS — DC
4.80
4.72
4.61
4.48
4.30
4.09
3.86
3.59
3.53
3.28
2.99
2.67
2.36
2.06
1.76
1.52
1.29
1.09
0.92
0.77
0.65
0.55
0.46
0.39
0.33
0.28
0.24
0.23
NOMINAL
MAXIMUM
THERMISTOR
VOLTS — DC
4.82
4.84
4.75
4.77
4.65
4.68
4.52
4.55
4.35
4.40
4.16
4.21
3.92
3.98
3.66
3.72
3.60
3.66
3.36
3.43
3.05
3.11
2.73
2.79
2.42
2.47
2.11
2.16
1.83
1.88
1.57
1.63
1.34
1.40
1.14
1.19
0.97
1.02
0.82
0.87
0.69
0.74
0.59
0.63
0.50
0.53
0.42
0.45
0.36
0.39
0.31
0.33
0.26
0.28
0.25
0.28

Hide quick links: