Toshiba RAS-24UFHP-E5 Service Manual page 76

Under ceiling/console type
Table of Contents

Advertisement

Part name
No.
2
Running
capacitor
for compressor
3
Running
capacitor
for fan motor
4
Magnetic
contactor
5
Spark killer
(Cooling only model)
Transformer
6
(Heat pump model)
Transformer
7
(Heat pump model)
Procedures
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 16L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screws ∅4 x 10L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 10L)
3) Disconnect the housing from the P.C. Board.
1) Perform the common procedure 1
2) Disconnect the lead wires from the P.C. Board.
3) Remove P.C.Board after unhooking 4 clams.
Running capacitor
for compressor
Running capacitor for
compressor
– 75 –
FILE NO. SVM-06006
Remarks
Spark killer
Running capacitor
for fan motor
Magnetic contactor
Cooling only model
Running capacitor
for fan motor
Magnetic
Transformer
P.C. Board
Heat pump model

Hide quick links: