Ras-24Ufp-E5 / Ras-24Na-E; Ras-24Ufpx5 / Ras-24N2Ax - Toshiba RAS-24UFHP-E5 Service Manual

Under ceiling/console type
Table of Contents

Advertisement

5-4. RAS-24UFP-E5 / RAS-24NA-E

RAS-24UFPX5 / RAS-24N2AX

0.39m
(Connecting pipe)
∅15.88 mm
0.39m
(Flexible pipe)
P
∅15.88 mm
O.D.:15.88 mm
Packed valve
(∅15.88 )
Cooling
Compressor
PH400X3CS-4KT1
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.
Indoor unit
Evaporator
Multi blade fan
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
exchanger interchanging
pressure P
pipe T (°C)
(MPaG)
0.43
0.56
0.30
– 19 –
FILE NO. SVM-06006
T
Packed valve
(∅6.35)
Capillary tube
∅2.4x700S
Refrigerant
R-22 1.68kg
Mark (
) means check points of Gas Leak
Fan speed
(indoor)
11.0
High
12.0
High
1.0
Low
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15