Toshiba RAS-24UFHP-E5 Service Manual page 13

Under ceiling/console type
Table of Contents

Advertisement

3-4. RAS-24UFP-E5 / RAS-24NA-E
RAS-24UFPX5 / RAS-24N2AX
COLOR IDENTIFICATION
BRW
:
BROWN
RED
:
RED
WHI
:
WHITE
YEL
:
YELLOW
BLU
:
BLUE
BLK
:
BLACK
GRY
:
GRAY
PNK
:
PINK
ORN
:
ORANGE
GRN&YEL :
GREEN&
YELLOW
GRN
:
GREEN
PUR
:
PURPLE
GRN&YEL
POWER SUPPLY
220 − 240 V ~ 50 Hz
OUTDOOR
TERMINAL
L
BLOCK
BLK
BLK
LOUVER
MOTOR
SG01
R09
R507
BLK
P04
R22
F01
FUSE
T6.3A
250VAC
R21
BLK CN30
WHI
CN31
CR02
RED
RY04
CN27
1 1
3 3
J401
2 1
CN402
CN401
FOR FLOAT SWITCH
(OPTION)
When you use float
switch you should
cut J401
INDOOR
1
2
3
TERMINAL
BLOCK
1
2
3
N
GRN&YEL
RED
CHASSIS
RED
BLK
BLK
GRY
SPARK KILLER
52C
A2
A1
RED
RED
1/L1 2/T1
CAPACITOR
3/L2 4/T2
5/L3 6/T3
MAGNETIC CONTACTOR
ORN
RED
PNK
YEL
BRW
BLU
6 5 4
3 2 1
CN07
6 5 4
3 2 1
IC04
MAIN PCB
MCC-865A
L01
C15
RY501
RY401
R405
C501
CR401
1
2
3
1 2 3
5
3
1
CN11
1 2 3
5
3
1
FOR DRAIN PUMP
(OPTION)
RED
BLK
BRW
GRY
YEL
INDOOR
UNIT
OUTDOOR
UNIT
RED
WHI
CAPACITOR
RED
WHI
S
FAN MOTOR
PNK
C
BLK
C
R
S
COMPRESSOR
COMPRESSOR TERMINAL
− 12 −
FILE NO. SVM-06006
INFRARED RAYS RECEIVE
AND INDICATION PARTS
1 2 3
4 5 6
7 8 9
10
CN25
1 2 3
4 5 6
7 8 9
10
1 2 3
4 5 6
7 8 9
10
CN13
1 2 3
4 5 6
7 8 9
10
CN100
CN101
WHI
1
1
GRY
2
2
GRY
3
3
R01
DB01
C01
C02
CR502
DC12V
DC5V
CN03
BLK
1 1
BLK
IC03
CR501
2 2
CN01
BLK
1 1
BLK
2 2
R506
CN10
BLK
WHI
WHI
1 1
RED
FAN
3 3
MOTOR
PUR
6 6
BLU
3 3
2 2
GRY
1 1
BLK
R
SWITCH
1
PCB
2
3
MCC-865B
THERMO
SENSOR
(TA)
HEAT
EXCHANGER
SENSOR
(TC)