Toshiba RAS-24UFHP-E5 Service Manual page 48

Under ceiling/console type
Table of Contents

Advertisement

CAUTION
Wrong wiring connection may cause some
electrical parts burn out.
Be sure to comply with local codes on running
the wire from indoor unit to outdoor unit (size of
wire and wiring method etc.)
Every wire must be connected firmly.
NOTE :Connection cable
Wire type : More than 1.5 mm
2
IEC66) or 1.3 mm
(AWG-16)
8-6. How to Set Remote Control Selector
When two indoor units are installed in seperated
rooms, there is no need to change the selector switch.
<Remote control selector switch>
• When two indoor units are installed in the same
room or the adjacent two rooms, they may be
controlled simultaneously with a single remote
control. To prevent this, set either unit and its remote
2
(H07RN-F or 245
control to B setting. (Both units are set to A setting
before shipment.)
• The remote control signal is not recived when the
indoor unit setting is different from the remote
control one.
1. Set the remote control selector switch with the
indoor unit.
1) Turn the circuit breaker of the main power switch off
before setting the selector switch.
2) Remove the Air inlet grille. (Refer to 8-4-2)
3) Select the terminal of selector switch from [A
position] to [B position].
– 47 –