LDVR Series Direct Vent Gas Fireplace
Wiring Instructions
The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electric Code.
For USA installations follow the local codes
and the national electrical code ANSI/NFPA
No. 70.
Should this fan require servicing or repair
the power supply must be disconnected.
For rewiring of any replacement parts refer
to Figure 55.
Any electrical rewiring of this fan must be
done by a licensed electrician.
Temperature Sen-
sor
Speed
Control
Black
White
Ground
Fig. 55 FK24 fan wiring.
Ceramic Refractory Kits
Ceramic refractory panels are available in kit form for
the LDV series appliances
Appliance Model
33LDVR
36LDVR
39LDVR
43LDVR
Take care when handling the refractory
panels as they are fragile until held in place
and supported.
Installation Refer to Figures 56 & 57
1. Remove the front window frame assembly.
2. Remove the logs.
3. Place the rear refractory panel in place. Locate the
lower edge of the panel in the ledge formed by the
top of the rear log support bracket.
4. Slide the side refractory panels into place to hold
the rear panel secure. Repeat the procedure on the
other side.
5. Replace the logs and window frame assembly.
For aesthetic purposes we recommend aligning the
horizontal mortar lines.
36
Fan
FP1025
FP394
WIRING DIAGRAM
11/20/96
Kit Name
33LDVRCR
36LDVCR
39LDVCR
43LDVCR
Side
Back Panel
Panel
Log Support
Burner Tray
FP1231
Fig. 56 Ceramic panel installation.
Rear Refrac-
tory Panel
FP1231
Ceramic panels
Rear Panel
11/02
Support
Brackets
Rear Log
Support
Fig. 57 Rear refractory panel installation.

Remote Controls

FP1232
Optional remote control units are available to control
rear ceramic panel
different functions of the appliances
Model
Function/s Controlled
11/02
MRCI
ON/OFF
MRC2
ON/OFF and Temperature
MRC3
ON/OFF and Temperature
control with a digital display
and programmable 24 hour clock
IMT
Wall mounted thermostat control
(must be used in bedroom installations)