Summary of Contents for Majestic fireplaces 36LDVT 39LDVT
Page 1
INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier.
LDVT Series Direct Vent Gas Fireplace PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation &...
Installation & Operating Instructions This gas fireplace should be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code.
Locating Your Fireplace Fig. 2 Locate gas fireplace. A - Flat on wall B - Cross corner D - *Room divider E - *Flat on wall corner Y - 6” minimum Note (Fig. 2): ** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’...
LDVT Series Direct Vent Gas Fireplace Hearth A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305mm) or more from the front of the fireplace. Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is mandatory that the outer walls be insulated...
High Elevations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level. For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the cur- rent ANSI Z223.1/NFPA 54 and/or local codes hav- ing jurisdiction.
LDVT Series Direct Vent Gas Fireplace EB-1 Electrical Box The fireplace, when installed, must be elec- trically connected and grounded in accord- ance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations follow local codes and the national electrical code ANSI/ NFPA No.
CIRCUIT BOARD Fig. 9 SIT822 Valve with Synetek electronic control wiring diagram. Your fireplace is approved to be vented either through the side wall, or vertically through the roof. • Only CFM Corporation venting components spe- cifically approved and labelled for this fireplace may be used.
LDVT Series Direct Vent Gas Fireplace General Venting Information - Termination Location CFM145a VENT TERMINATION A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be opened C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2’...
Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Combustible 6" (152 mm) Noncombustible 2" (51 mm) Balcony - with no side wall Combustible & Noncombustible 12" (305 mm) *NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits.
LDVT Series Direct Vent Gas Fireplace Twist Lock Pipes When using CFM Corporation twist-lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section used in the system.
Page 13
20' (6m) Pipe Straps Every 3’ (914mm) Pipe Straps Every 3’ (914mm) Firestop/Zero Clearance Sleeve Fig. 14 Support straps for horizontal runs. FP1012 Horizontal plane means no vertical rise exists on this Top vent max run portion of the vent assembly. 1/25/00 djt •...
Page 14
LDVT Series Direct Vent Gas Fireplace Vertical Sidewall Installation Twist Lock Pipe STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size.
Page 15
STEP 5 Measure the horizontal length requirement including a 2” (51 mm) overlap, ie from the elbow to the outside wall face plus 2” (51 mm) (or the distance required if installing a second 90° elbow). (Fig. 21) Always install horizontal venting on a level plane.
LDVT Series Direct Vent Gas Fireplace Step 4 Install the 4” (102 mm) flex vent pipe to the appliance collar as described on Page 11. Secure the end with the first spring 6³⁄₄” (172 mm) from the flex pipe end to the unit.
Foundation Recess Recess Brackets Watertight Seal Around Pipe Fig. 27 Snorkel installation, recessed foundation. Vertical Through-the-Roof Applications BG401 Snorkel This Gas Fireplace has been approved for: 2/10/99 djt • Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90°...
LDVT Series Direct Vent Gas Fireplace Vertical Through-the-Roof Installation 1. Locate your fireplace. 2. Plumb to center of the (4” (102 mm) flue collar from ceiling above and mark position. 3. Cut opening equal to 9³⁄₈” x 9³⁄₈” (240 x 240 mm). 4.
Page 19
Vertical Restrictor Plate 36LDVT, 39LDVT, 43LDVT When installing the 36LDVT, 39LDVT or 43LDVT with a vertical through-the-roof configuration flue system, the restrictor plate (#10008048) supplied with the appliance MUST BE FITTED TO THE APPLIANCE at the instal- lation. NOTE: Do not use the restrictor plate supplied with the vertical termination cap.
Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate appliance with glass front removed, cracked or broken.
LDVT Series Direct Vent Gas Fireplace Installation of Logs, Lava Rock & Ember Material The logs are fragile and should be handled with care. Keep the packaging material out of the reach of children and dispose of the material in a safe manner. The individual logs can be easily identified by the numbers cast on the underside of each log.
Page 23
36LDVT 1. Place rear log (B158) on rear brack- et (ensure log is seated properly to the bracket and located to the two pins), so it will not move from side to side and is firmly positioned on the bracket. 2.
LDVT Series Direct Vent Gas Fireplace 43LDVT 1. Place rear log (BD15) on rear bracket (ensure log is centered and seated properly to the log support). 2. Place front left log (BD16). Use log’s bottom notch to locate it onto the front support and just rest on top of the burner housing assembly.
Page 25
LG384 LG384 33LDV log flames 1/05 LG415 ����� ����� ��� ������ ���� Fig. 44 Correct burner flame appearance for the LDVT fireplaces. 10007852 LDVT Series Direct Vent GaS Fireplace 33LDVT Glowing Embers 36LDVT 39LDVT Glowing Embers 43LDVT LG435 LG482 Glowing Embers �����...
LDVT Series Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- ally.
Page 27
Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life. FOR YOUR SAFETY READ THE FOLLOWING WARNINGS A.
LDVT Series Direct Vent Gas Fireplace Troubleshooting Honeywell Millivolt Valve START Gas Supply On Pilot Lights With Piezo Ignitor Pilot Stays Lit Pilot Lights Main Burner SYSTEM OK Remove Window Frame Assembly Before Service Work CHECK • Supply Line Hooked Up •...
Normal Operation ON/OFF Switch Closed? Safe Start Check On? 0 Sec Purge Ignition Trial: 30 sec Spark ON Pilot Valve ON. Has Flame been Detected within 30 sec? Spark Off. Main Valve ON. Pilot Flame Continuously Monitored Pilot Flame Sense OK? ON/OFF Switch Opened? Pilot and Main Valve OFF? 0 sec Post Purge?
LDVT Series Direct Vent Gas Fireplace CONVERTING THE APPLIANCE FROM LP TO NATURAL GAS OR NATURAL GAS TO LP The conversion of this appliance from one gas to another must be carried out by an authorized service provider. The procedure for converting from one gas to another is the same regardless of the initial gas used.
12. After bleeding the gas line and checking for leaks with a soap solution, replace the window frame assembly. Fire up the unit, check for flame impinge- ment on the logs, adjusting them if necessary. Check manifold and supply pressures against appliance specifications.
LDVT Series Direct Vent Gas Fireplace 33LDVT 18a,b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, with out notice. 33/36/39/43LDVT 33LDVT units: GFTN2I0, GFTL2I0, GFTE2I0 36LDVT units: GFTN2J1, GFTL2J1, GFTE2J1 39LDVT units: GFTN2K0, GFTE2K0 43LDVT units: GFTN2N0, GFTE2N0 36LDVT...
Page 33
33/36/39/43LDVT Ref. Description Log Set (complete) Front Left Log Front Right Log Front Center Log Rear Log Rear Left Log Rear Right Log Top Center Log Lava Rock Package Ember (Package) Burner Housing Assy - Natural Burner Housing Assy - Propane Ceramic Tile (Single) Orifice Burner - Natural Orifice Burner - Propane...
Page 34
LDVT Series Direct Vent Gas Fireplace 33/36/39/43LDVT Ref. Description 33a. Support Rear Log - Natural 33b. Support Rear Log - LP Support Front Log ON/OFF Switch Relief Plate Assy (Burner Base) Remote Switch Kit (Not Shown) Ignition Control from Synetek (EN) Wire Harness (EN) Synetek (low voltage) Wire Harness (EN) Synetek (high voltage) Restrictor Plate...
Fan Kits FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit. Specifications 115 Volt / 60Hz / 56 Watts Maintenance...
LDVT Series Direct Vent Gas Fireplace Wiring Instructions The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code. For USA installations follow the local codes and the national electrical code ANSI/NFPA No.
PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions...