2-3 Other Component Specifications

4-way Valve (20S)
Coil rating
Coil resistance
Electronic Expansion Valve
Coil rating
Coil resistance / phase
Defrost Valve
Coil rating
Coil resistance
Thermistor (coil sensor)
Resistance
Thermistor (compressor disch. sen.)
Resistance
Thermistor (inlet air sensor)
Resistance
Thermistor (wide tube A sensor)
Resistance
Thermistor (narrow tube A sensor)
Resistance
Thermistor (wide tube B sensor)
Resistance
Thermistor (narrow tube B sensor)
Resistance
Crank case heater
Resistance
Base heater
Resistance
GR9FI50R5IAA
SQ-136 (Coil)
SHF-4H-23U (Valve)
Ω (at 20°C)
Ω (at 20°C)
Ω (at 20°C)
kΩ
kΩ
kΩ
kΩ
kΩ
kΩ
kΩ
Ω (at 20°C)
Ω (at 20°C)
DATA SUBJECT TO CHANGE WITHOUT NOTICE CHANGE WITHOUT NOTICE
7
GR9FI50R5IAB
SQ-136(Coil)-SHF-7K-34U(Valve)
STF-..J514.. (coil) - STF-0202G (valve)
AC 220/240 V, 50 Hz
1440 ± 5%
CAM-MD12EX(Coil)
DC 12 V
46 ± 4%
FQ-235-RK (Coil)
FDF6A-049-RK (Valve)
AC 220/240 V - 50 Hz
1273 ± 10%
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
30 W RESISTANCE
1760 ± 10%
75W FLEXELEC CSC2
705 ± 10%
GR9FI42R5IAA
ZCAM-BD15EX (Valve)