How to replace the thread lifters (dia.
35 + 36)
^ Use a suitable screwdriver to remove
the thread lifters from the slots.
^ Fit new thread lifters.
How to clean the roller on floorhead
SBD 285-3 (dia. 37)
a Release the bearing (with bayonet
fitting) using a coin.
b Press the bearing out, and remove.
c Remove the roller.
^ Remove any threads and hair,
replace the roller and refit the
bearing, locking it back into position.
Replacement parts are available from
your Miele Dealer or from Miele (see
end of booklet for contact details).

Cleaning and care

,
Always disconnect the vacuum
cleaner from the electrical supply
before cleaning it. Switch off at the
wall socket and unplug it.
Vacuum cleaner and accessories
The vacuum cleaner and all plastic
accessories can be cleaned with a dry
or a slightly damp cloth, or with a
proprietary cleaner suitable for plastic.
,
Do not use abrasive cleaning
agents, glass cleaning agents,
all-purpose cleaners or oil-based
conditioning agents.
Dust compartment
The dust compartment can, if
necessary, be cleaned using a dry
duster, brush or, if available, a second
vacuum cleaner to vacuum the dust
out.
,
Do not let the vacuum cleaner
get wet. If moisture gets into the
appliance, there is a risk of electric
shock.

Problem solving guide

The vacuum cleaner switches off
automatically.
A temperature limiter switches the
vacuum cleaner off automatically if it
gets too hot.
This can occur if, for instance, large
articles block the suction tube or when
the dustbag is full or contains particles
of fine dust. A heavily soiled exhaust or
dust compartment filter can also be the
cause of overheating. Switch the
vacuum cleaner off immediately using
the On/Off foot control s. Disconnect
from the electricity supply. Switch off at
the wall socket and unplug it.
After removing the cause, wait for
approximately 20 - 30 minutes to allow
the vacuum cleaner to cool down. It
can then be switched on and used
again.