AXIS T8134 Midspan 60W
If an external power splitter is in use, verify that it works.
Verify that there is no short over on any of the twisted pair
cables or over the RJ45 connectors.
If possible reconnect the same powered device into a different
midspan.
The end device operates, but there is no data link
Verify that the port on the front panel is continuously lit.
Verify that a standard Category 5/5e/6, straight-wired cable
with four pairs is used.
Verify that the Ethernet cable length is less than
100 m (330 ft) from the Ethernet source to the load/remote
terminal.
If an external power splitter is in use, verify that it works.
If possible reconnect the same powered device into a different
midspan.