Programmer/Receiver settings
5.2

Installer

These functions are only used by the installer/service engineer
and are useful during installation.
Press the menu button and return button for more than three
seconds to enter the Installer setting area of the programmer.
Five user icons are shown across the top of the display, plus the
sixth that is the Installer icon:
1. Heating
2. Hot water
3. Holiday
4. Info
5. Settings
6. Installer setting
Selections 1 to 5 are the same as the Programmer/Receiver
user menu,  section 5.1.
Turn the knob to select the Installer icon
knob to enter the function.
2
3
1
pmam
Fig. 14
Installer menu
Installer settings menu options
1. Reset all
2. Maintenance
3. System info
4. Radio settings
The menu options are displayed on the top line with flashing left
and right arrows heads, indicating that there are other menu
options available. Turning the knob will select each option in
turn, eventually returning to the first option.
1. Reset all
▶ Press the knob and NO flashes
▶ Turn the knob to select NO or YES
14
and press the
5
6
4
▶ Press the knob to confirm, if YES is chosen all menus within
the Installer menu are reset back to default settings, four
bars progress across the display until the reset has taken
place,
if NO is chosen, no reset takes place
2. Maintenance
a. Fault history
– Cont. faults
b. Landlord func.
– Maint. date
– Maint. contact
a. Fault history
▶ Press the knob and Cont. faults is displayed
▶ Press the knob and the first of five faults is displayed with
the fault code and occurrence date. The fault screens can
be scrolled through using the knob. If no faults have
occurred, the text No fault will be displayed.
b. Landlord func.
This function is for social housing landlords only and enables a
maintenance/annual service date to be set.
The maintenance reminder message "Maintenance" is
displayed 30 days before the set date.
Along with the Maintenance message a contact telephone
number will be displayed.
The tenant should call this number to arrange a convenient date
for the service.
Landlords, call the Worcester Bosch technical support team for
instructions of how to reset the Maintenance message or
contact telephone number.
If the maintenance reminder message is not cleared or reset to
a later date, by the Service engineer, then 14 days after the
scheduled maintenance date the controller will limit the room
temperature set point to 18°C.
3. System info
▶ Turn the knob to select System info
▶ Press the knob and Install date flashes
▶ Press the knob and the install date is displayed
▶ Press the knob to return to Install date
▶ Turn the knob to select SW controller
▶ Press the knob to display the software controller version
▶ Press the knob to return to SW controller
▶ Press the return button
4. Radio settings - Pair/Unpair
The Programmer/Receiver and Room
thermostat are delivered together and are
factory paired, they will automatically
connect when the system is switched on.
If the a units have to be paired, all units must be
in the pairing mode to be connected, refer to
section 6.5 to put the Room thermostat into
the pairing mode.
to go back to System info
Comfort I – 6720810964 (2014/07)