Initial Set-Up & Electrical Requirements - Bunn JDF-4 Installation & Operating Manual

Table of Contents

Advertisement

CAUTION: The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move
the dispenser. Place the dispenser on a sturdy counter or shelf able to support at least 230 lbs. (104.3 kg). The
JDF-4 is designed for indoor use only.
Set the dispenser on the counter where it will be used. The JDF-4 requires a minimum of 4 inches (102 mm)
of air clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is
required between the dispenser sides and the wall or another appliance. For optimum performance, do not let warm
air from surrounding machines blow on the JDF-4. Leave some space so the dispenser can be moved for cleaning.
CAUTION: The dispenser must be disconnected from the power source until specified in Electrical Hook-Up .
The dispenser has an attached cord set and requires a 2-wire, grounded, individual branch circuit rated 120 volts
ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA5-15R. (Refer to the dataplate for exact
electrical requirements.)
ELECTRICAL HOOK-UP
CAUTION: Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Connect the dispenser to the power source.
4. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing
has been hooked up, the dispenser is ready for Initial Fill .
INITIAL SET-UP
ELECTRICAL REQUIREMENTS
4
33854 092101