Advertisement

EVOLUTION
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the ad-
dress or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qual-
ified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society of Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. This product may have sharp edges. Be careful to avoid cuts
and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Use only metal ductwork.
9. Do not use this fan with any solid-state speed control device.
10. As an alternative, this product may be installed with the UL-
approved cord kit designated for the product, following in-
structions packed with the cord kit.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ig-
nite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambéing food (i.e. Crêpes Suzette, Cherries Jubilee, Pep-
percorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PRE-
VENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
Register your product online
3
TM
at: www.broan.com
FOR DOMESTIC COOKING ONLY
WARNING
2. NEVER PICK UP A FLAMING PAN — You may be burned or
spread the fire.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Firesafety Tips" published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbal-
anced impeller, keep drywall spray, construction dust, etc.,
off power unit.
4. Do not use over cooking equipment greater than 60,000
BTU/hr. as the blower motor will shut down intermittently.
5. Your hood motor has a thermal overload which will automati-
cally shut off the motor if it becomes overheated. The motor
will restart when it cools down. If the motor continues to shut
off and restart, have the hood serviced.
6. The top of the hood MUST NOT BE LESS than 24" and at a
maximum of 30" above cooktop for best capture of cooking
impurities.
7. This hood is not intended to be used as a shelf.
8. Please read specification label on product for further infor-
mation and requirements.
NOTE
If hood is to be installed non-ducted:
Purchase a set of (2) non-ducted filters for 30" wide
hoods (Model BPPF30) & 36" wide hoods (Model
BPPF36) or a set of (3) non-ducted filters for 42" wide
hoods (Model BPPF42) from your local distributor or
retailer and attach them to the aluminum mesh filters.
Installer: Leave this manual
with the homeowner.
Homeowner: Cleaning, Maintenance and
Operating instructions on pages 2-4.
QP3 SERIES
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Broan EVOLUTION 3

  • Page 1 QP3 SERIES Page 1 Register your product online EVOLUTION at: www.broan.com READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- 2. NEVER PICK UP A FLAMING PAN — You may be burned or JURY TO PERSONS, OBSERVE THE FOLLOWING: spread the fire.
  • Page 2: Operation

    QP3 SERIES Page 2 OPERATION 10-MINUTE DELAY OFF When your hood fan is on (any speed) press the button to Always turn the hood ON before cooking in order to establish an activate the delay off feature. When activated, the hood fan will air flow in the kitchen.
  • Page 3 QP3 SERIES Page 3 CLOCK SETTING HEAT SENTRY SYSTEM This range hood is equipped with an advanced Heat Sentry Press the button once, the “hours” will begin blinking in the system that monitors excessive temperature and automatically LED screen. Use the buttons to set the appropriate adjusts the fan to the appropriate setting.
  • Page 4: Light Bulb Replacement

    QP3 SERIES Page 4 MAKE-UP AIR DAMPER Stainless Steel Cleaning The hood is compatible with Broan Make-Up Air Damper Model MD6T or Model MD8T (optional). Purchase separately. • Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
  • Page 5: Prepare Hood Location

    QP3 SERIES Page 5 PREPARE HOOD LOCATION LAMP SOCKET BRACKET Use the proper diagram below, for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole. 3¼” X 10” VERTICAL DUCTING HOOD MOUNTING SCREWS (5) "...
  • Page 6: Measure The Installation

    QP3 SERIES Page 6 MEASURE THE INSTALLATION PREPARE THE HOOD Remove parts bag from inside the hardware box included ROOF CAP 3¼" X 10" or with the hood. 7" ROUND DUCT (For vertical Remove all protective polyfilm from the hood (stainless discharge) steel hoods only).
  • Page 7 QP3 SERIES Page 7 15 NON-DUCTED INSTALLATION ONLY: Purchase a set of (2) non-ducted filters for 30” wide hoods (Model BPPF30) & 36” wide hoods (Model BPPF36) or a set of (3) non-ducted filters for 42” wide hoods (Model BPPF42) from your local distributor or retailer. Attach the non-ducted filters to the aluminum mesh filters following NON-DUCT instructions packed with the non-ducted filters.
  • Page 8: Install The Hood

    QP3 SERIES Page 8 INSTALL THE HOOD CONNECT THE WIRING WARNING To reduce the risk of electrical shock, switch power off at service panel. Lock or tag service panel to prevent power from being switched on accidentally. GROUND SCREW ELECTRICAL WIRING BOX COVER HOUSE...
  • Page 9: Service Parts

    User Interface Assembly White (includes interface, which vary from state to state. This warranty supersedes all prior warranties. nameplate, mounting hardware) To qualify for warranty service, you must (a) notify Broan-NuTone at the 97018257 User Interface Assembly Black (includes interface,...

This manual is also suitable for:

Qp3 seriesEvolution 3 qp3 series

Table of Contents