Download Print this page

Curtis TXSG0101S600 Service Manual

Txsg server

Advertisement

Quick Links

BREWING INTO THE TXSG SERVER
1. Make sure the control panel screen reads READY TO BREW.
2. Place a clean and empty server centered under the brew cone of your coffee brewer.
3. Remove the top cap from the lid.
4. Fill brew cone with the correct measure of ground coffee.
5. Select the BREW button that matches the brew volume. Press the BREW button to start the
brew.
Models
6. Allow coffee in the brew cone to completely drip out before removing the coffee server.
Ÿ TXSG0101S600
Ÿ TXSG1501S600
Ÿ TXSG0101S200
Ÿ TXSG1501S200
SERVICING THE THERMOPRO SERVER
1. Completely drain the unit of any coffee.
2. Allow server to cool.
3. Unscrew and remove the lid and tube assembly.
REPLACING THE GAUGE GLASS
The gauge glass can be removed for maintenance and cleaning. Refer to the illustration on page three [3] for assembly sequence.
1. Unscrew the vented cap plug from the top of the gauge glass shield.
2. Carefully lift out the gauge glass tube from the shield and scrub inside the glass with a tube cleaning brush and mild detergent
solution. Inspect the glass tube for cracks or chips. If broken, carefully remove all traces of glass and insert a new glass tube.
3. Check the top and bottom washers. Clean the washers. Make sure they are not leaking. Replace if necessary.
4. With the sight glass seated in the gauge glass shield, thread the cap plug onto the top of the shield. Do not overtighten.
REMOVING THE BASE & BOTTOM COVER
To replace the silicone elbow fitting for repair or cleaning:
1. Remove the base assembly. Press down on the slide tab in back of the stand and lift off the server.
2. Turn the server upside down and take off the plastic bottom cover, revealing the silicone elbow fitting.
3. Remove the wire hose clamps by squeezing the wire ears together. While holding the clamp open,
loosen the soft silicone elbow from the liner drain pipe and the faucet shank and pull out elbow.
4. Check for leaks and replace with a new elbow if necessary.
5. Reverse these steps to assemble.
REMOVING THE FAUCET
The faucet will require periodic cleaning and maintenance.
1. Remove the faucet from the body of the server. Unscrew the large nut holding the faucet to the shank
to take off the faucet.
2. Disassemble the faucet. Unscrew the bonnet from the body of the faucet.
3. Remove the faucet handle by pressing inward on the seat cup (see photo at right) then unhooking the
handle from the center shaft.
4. The seat cup, center shaft and spring will now separate from the bonnet. Clean these parts with a mild
detergent solution.
5. While you have these parts disassembled for cleaning, check the condition of the seat cup. Make sure
the faucet spring is free of corrosion. Replace these parts with repair kit if necessary (item 19, page 3).
ASSEMBLY
Assemble the unit by reversing the steps for disassembly. Finger tighten wing nut onto faucet. Make sure
clamps are fastened properly and silicone fittings are in good condition. Once assembled, check for leaks around the fitting and
faucet.
W
ilbur
Service Manual – TXSG Server
WARNING – Thermopro servers may be heavy when filled.
Care must be taken when transporting to avoid dropping or spilling.
C
C
., i
urtis
o
nC
.
1

Advertisement

loading

Summary of Contents for Curtis TXSG0101S600

  • Page 1 5. Select the BREW button that matches the brew volume. Press the BREW button to start the brew. Models 6. Allow coffee in the brew cone to completely drip out before removing the coffee server. Ÿ TXSG0101S600 Ÿ TXSG1501S600 WARNING – Thermopro servers may be heavy when filled. Ÿ TXSG0101S200 Care must be taken when transporting to avoid dropping or spilling.
  • Page 2: Cleaning Instructions

    Cleaning Instructions 1. In a container, mix a mild detergent and warm water solution for cleaning the coffee server. 2. Discard old coffee from the coffee server. 3. Remove and clean the lid. 4. Clean inside the coffee server with a sponge brush soaked in detergent solution. 5.
  • Page 3 Illustrated Parts...
  • Page 4 (22.9 cm) (36.5 cm) Product Warranty Information Wilbur Curtis Co., Inc. certifies that its products are free from defects in material and workmanship under normal use. The following limited warranties and conditions apply: 1 year from the original date of purchase.

This manual is also suitable for:

Txsg1501s600Txsg0101s200Txsg1501s200