All Freezer-Pro
Light Shield Removal
To remove the light shield, extract the two screws
securing the light shield to the compartment ceiling.
Light Fixture Removal
The light fixture is secured with retaining latches into the
interior cabinet ceiling behind the light shield.
(See Figure 5-41)
To remove the light fixture:
1. Remove light bulb by turning counter-clockwise.
2. Pull down on the front of the light fixture while
turning the fixture a quarter turn to release the
retaining latches.
3. Disconnect wire leads from light fixture terminals.
Baffle Plate Removal
To remove the baffle plate, with one hand grab the
baffle plate from the center and pull back while with
the other hand, reach behind to disengage the retaining
latches. (See Figure 5-42)
Ice Maker Removal
The icemaker is mounted with two 1/4" hex head
screws to the upper left hand corner of the freezer
compartment. (See Figure 5-43)
To remove the ice maker:
1. Remove uppermost glass shelf and ice bucket.
2. Using a 1/4" extended socket or nut driver, extract
the two screws securing the icemaker to the left
sidewall of the unit.
3. Disconnect wire leads from icemaker at the quick
disconnect mounted in the upper left corner of the
freezer compartment.
Section 5 Component Teardown
Light Bulb
Screw
Light Shield
Figure 5-41. Light Shield and Fixture Removal
Baffle Plate
Figure 5-42. Baffle Plate Removal
Screws
Figure 5-43. Ice Maker Removal
Light Fixture
Light Bulb
Screw
Electrical Connection
5-19