Troubleshooting - Winnebago 2006 Outlook Operator's Manual

Table of Contents

Advertisement

To Retract the Slideout Room
See Operation Safety Precautions before
proceeding.
To retract the room, press and hold the "IN"
button.
Press to
Retract
To stop retracting the room during operation,
release the button.
When the room has retracted completely, it
will stop automatically.
After the room has been retracted, refasten the
safety travel straps.

TROUBLESHOOTING

Battery Voltage or Circuit Breaker
Problems
If the slideout room will not work:
Τhe chassis battery may be low on charge.
Press and hold the Battery Boost switch on the
dash while pressing the slideout control
switch. This momentarily connects the coach
batteries to assist in retracting the room.
The circuit breaker may be tripped. The
circuit breaker, labeled 'Slideout Power' is
located on a panel on an interior wall of the
passenger side storage compartment just
behind or ahead of the entrance door.
Press to
Extend
Problems Retracting the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Retract button.
Green light will flash
error code if system
Diagnostics
Reset Button*
*Not equipped on single mechanism systems
If an error is detected on your DigiSync Room
Slide System, the green LED on the left side of
the control panel will blink an error code. If an
error code appears, see the On Board diagnostics
section to determine the problem. The error code
must be cleared prior to operating the room. To
clear the error, press the "RESET" button with a
small tool such as a toothpick. Before operating
the room after an error has been detected, check
for obvious faults such as obstructions prior to
trying to operate the room again. If the error code
appears again, the room will need to be retracted
using either the manual retraction method or the
fully manual method. Both methods listed below
are intended as a means to retract the room to
prepare the coach for travel to the nearest
authorized Service Center.
To retract the room after an error is detected,
you override the synchronization programming
and operate the room in the Manual Mode.
Manual Mode:
Manual Mode lets you individually move the
two room arms by pressing the IN and OUT
buttons on the control pad. This mode can be used
SECTION 10
SLIDEOUT
Red light will flash if
park brake not set.
10-3

Advertisement

Table of Contents
loading

Table of Contents