g SYNC (sync signal output) connector
Outputs a sync signal for connection to the sync signal input
connector of a waveform monitor or picture monitor.
h REMOTE connector (8-pin)
Transmits and receives control signals from a MSU-1000/1500
Master Setup Unit or RCP-1000-series Remote Control Panel
via a CCA-5 cable (optional). It also supplies power when
connected to an RCP-1000-series Remote Control Panel.
i MIC OUT1, MIC OUT2 (microphone output 1, 2)
connectors (XLR 3-pin)
Outputs the camera microphone signals.
j CAMERA connector (triax connector)
Connects to the camera via a triax cable. The camera sends
all video and audio signals to the CCU, and the CCU sends
control signals, return video and audio signals, as well as
power, to the camera over a single triax cable.
k AC supply input connector
Connects to the AC supply via the specified power cord
(optional). A plug holder (optional) can be used to secure the
power cord to the CCU.
l REFERENCE (reference input) connectors (BNC type)
Inputs an HD tri-level reference sync signal or SD reference
sync signal (black burst signal) on either of the two connectors.
The input signal is output from the other connector as-is (loop-
through output). If the loop-through output is not used, connect
it to a 75 Ω terminator.
m INTERCOM/TALLY/PGM (intercom/tally/program
audio) connector (D-sub 25-pin)
Transmits and receives the various intercom, tally, and
program audio signals. It connects to the intercom/tally/
program audio connector of the intercom system.
n RETURN INPUT (return video input) connector block
• SDI 1/3, 2/4 (SDI return video 1/3, 2/4 input) connectors
(BNC type)
• VBS 1/3, 2/4 (VBS return video 1/3, 2/4 input) connectors
(BNC type)
Inputs the HD SDI return video signals and SD SDI return
video signals (2-system), and the VBS return video signals
(2-system).
For information on the return video signal combinations, see
"Return Signal Combinations" on page 29.
o MIC REMOTE (microphone remote) connector
(D-sub 15-pin)
Connects to an external control device, such as an audio
mixer, which can select the camera microphone gain to one of
five values (20/30/40/50/60 dB) in response to the audio
conditions when shooting.
This connector can also output a red tally signal and green
tally signal.
p WF REMOTE (waveform monitor remote) connector
(D-sub 15-pin)
Outputs signals for a waveform monitor when controlling the
waveform monitor display remotely from the MSU-1000/1500
Master Setup Unit or RCP-1000-series Remote Control Panel.
It connects to a recall-type waveform monitor.
For connection details, refer to the waveform monitor manual.
12
Locations and Functions of Parts
q Pr/R/R-Y, Y/G/Y, Pb/B/B-Y (component signals)
connectors (BNC type)
Outputs the HD component signals, SD component signals,
HD RGB signals, or SD RGB signals from the corresponding
connectors.
r TRUNK connector (D-sub 9-pin, RS-422A standard)
Connects to an external device to provide a communication
path via the CCU between that device and another external
device connected to the REMOTE connector on the camera.
s WF MODE (waveform monitor mode output) connector
(4-pin)
Connects to a waveform monitor and is used when monitoring
each of the 3 R/G/B waveforms simultaneously in sequential
mode.
When the SEQ button on the MSU-1000/1500 Master Setup
Unit or RCP-1000-series Remote Control Panel is pressed,
the video signal output from the WF connector changes to a
sequence signal.