v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7981 and 1884," on page 53 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
201-xxx-0nn
Failed memory test.
Note: nn = DIMM slot number, 01 to 04
201-xxx-n99
Multiple DIMM failure, see error text.
Note: n = number of failing pair; see
"Installing a memory module" on page 64.
202-xxx-00n
Failed system cache test.
Note: n = microprocessor 1 or
microprocessor 2.
217-198--xxx
Could not establish drive parameters.
217-xxx-000
Failed hard disk drive test.
Note: If RAID is configured, the SAS
Attached Disk number refers to the RAID
logical drive.
217-xxx-001
Failed hard disk drive test.
Note: If RAID is configured, the SAS
Attached Disk number refers to the RAID
logical drive.
405-xxx-000
Failed Ethernet test on controller on the
system board.
Action
1. Reseat the DIMM in the indicated slot.
2. Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a. DIMM in indicated slot
b. (Trained service technician only) System
board assembly
1. See the error text for failing DIMMs.
2. (Trained service technician only) Replace the
system board assembly.
1. Reseat microprocessor n.
2. Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a. (Trained service technician only)
Microprocessor n
b. (Trained service technician only) System
board assembly
1. Reseat hard disk drive x.
2. Update the BIOS code.
3. Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a. Hard disk drive x
b. (Trained service technician only) System
board assembly
1. Reseat hard disk drive 1.
2. Replace hard disk drive 1.
1. Reseat hard disk drive 2.
2. Replace hard disk drive 2.
1. Make sure that Ethernet is not disabled in the
Configuration/Setup Utility program.
2. (Trained service technician only) Replace the
system board assembly.